Step #2 – Install Strike
Install strike in the door frame (Fig.2A).
Step #3 - Install Latchbolt
1. Install latch with beveled bolt facing the strike.
2. Attach with two screws but DO NOT tighten
completely at this time.
IMPORTANT: Latch bevel must match door bevel and
deadlocking latch must stop on strike when door is closed.
Step #4 – Door Options
A..Fire.Stop.Plate.(P/N.52-0033)
Fire-rated doors require a fire stop plate on
the outside of the door (Fig. 4A).
1. Drill (2) 1/8" x 1-1/4" deep holes in the
door if not already present.
Refer to template for fire-stop
prep locations.
2. Attach with flap up and
out using (2) #8 x 1/2"
self-tapping screws for
wood and metal doors.
B..Weather.Conduit.(52-2847)
Install weather conduit on
exterior doors only (Fig. 4B).
NON.FIRE-RATED
1. Carefully insert the weather conduit into the
ribbon cable hole on the inside of the door.
2. Place the O-ring around the weather conduit
on the outside and up against the door (Fig. 4C)
12
A7763B
Profile Series v.S1 PoE Cylindrical Lock
Centerline of Latch
(2) #8-32 x 3/4"
Latch Screws
Fig...2A
Strike
Deadlocking Latch
Fig...3B
Front and Strike
(2) 1/8" Diameter
Holes Required
Fire Stop Plate
(2) #8 Self-Tapping
Screws for Wood
and Metal Doors
(2) Through-bolt Holes
Fig..4A
Outside.of.Door
Ribbon Cable Hole
Fig.4B
Outside.of.Door
Fig..3A
O-Ring
Fig.4C
Outside.of.Door