Revision History Rev. Details Initial Release Added description of what other features are affected when Passage Mode is enabled. Fixed Minimum value for Auto Relock Time and fixed Default Value for Auto Relock Feature; Removed Inside LED Column for Indicator CC since this lock does not have Inside LED.
Yale Z-Wave Plus ™ Product Info Manufacturer ID: ASSA ABLOY (0x0129) Z-Wave™ Device Type: Door Lock Keypad Z-Wave™ Role Type: Listening Sleeping Slave (LSS) Network Operations Enroll/Add device to network (SmartStart) SmartStart enabled products can be added into a Z-Wave™ network by scanning the Z-Wave™...
Un-enroll/Remove device from network (Exclusion Mode) • Enter the 4–8-digit Master PIN code followed by the key. • Press the key followed by the key. • Press the key followed by the key. When the Yale lock is unenrolled/excluded from the network through the device menu mode, any changes previously made to the user code database and configuration settings will be retained, as opposed to set back to defaults.
* This command class requires security. The Manufacturer Specific command class reports the following information: • Manufacturer ID: 0x0129 o This is the manufacturer ID assigned to ASSA ABLOY. • Product ID: o The Product ID can be used to differentiate between hardware platforms, as well as between ZW2 and ZW3.
Command Class Security, Version 1 This command class has been implemented per the Z-Wave™ Specification. Command Class Security 2, Version 1 This command class has been implemented per the Z-Wave™ Specification. Command Class Device Reset Locally, Version 1* * This command class requires security. The Yale door locks covered in this guide can be reset to their factory default settings by manually resetting the lock by following the procedure outlined in the specific lock’s manual.
Command Class Version, Version 3* * This command class requires security. The Yale Real Living locks are a multi-processor system with 1 additional firmware target. All processors can be updated through the Firmware Update Meta Data command class. The firmware targets are numbered as follows: •...
Command Class Battery, Version 1* * This command class requires security. Per the Z-Wave Plus ™ Specification, the lock will send a Battery Report with a value of 0xFF to the Lifeline node when a critical battery level is reached (starting at about 4.2V for Product Type ID 0x8101 &...
Command Class User Code, Version 2* * This command class requires security. Versions 1 and 2 of this command class can address user code slots 1 through 250 via the User Code Set/Get/Report commands. Version 2 of this command class also includes extended versions of each of these commands, used to address the extended range of users.
Page 12
• Previously, a value of 0x04 was reserved for setting non-Access users, as stated above. When using version 2 of this command class, a non-Access (now called “Messaging”) user ID status is assigned a value of 0x03. This value of 0x03 should be used with the Extended User Code Set command. •...
Page 13
User ID User Code CC v2: Extended User Code CC v2: Extended User Status User Code Set Code Report Value Description Value Value Available 0x00 0x00 Enabled / Grant 0x01 0x01 Access Disabled 0x02 0x02 Messaging: The user code is accepted, but the lock does not grant access to the...
Command Class Time Parameters, Version 1* * This command class requires security. The controller must set the Time Parameters in the lock anytime the lock loses power. After 10 seconds from lock enrollment, if there are no messages from the controller the lock will initially request the Time (by sending Time Get and Time Parameter Get commands).
Firmware Target 0 is used to determine the correct Z-Wave™ processor image to download. ID 1 is always 0xA5, to signal this is an ASSA ABLOY Z-Wave™ image, and ID 2 is specific to the region, with the lower nibble being 0x0 and the upper nibble being the value in Table 4 - Region-Specific Values for Firmware ID 0.
The following is the time it takes for each product to complete OTA image apply phase: • For Z-Wave™ Radio Chip, ~10 seconds • For NTB612/622/632/642-ZW3 (2nd Generation Cylindrical lock), ~23 minutes • For NTB612/622/632/642-NN-ZW3 (2nd Generation Cylindrical lock with No NFC), ~23 minutes Command Class Association, Version 2* * This command class requires security.
Command Class Association Group Info, Version 3* * Command Class Requires Security Yale locks support the Lifeline Association Group. Table 5 - Association Table Group ID Maximum Nodes Description Commands • Command Class Battery Battery Report • Command Class Configuration Configuration Report •...
Page 18
The following are the actions to trigger the reports: Table 6 – Lifeline Report Trigger Table Report Command RF Trigger Manual Trigger Battery Report Any RF Lock Operation when lock is Any manual/keypad Lock Operation under the battery thresholds when lock is under the battery thresholds or Power Cycle Lock Configuration Report Configuration Set...
Command Class Notification, Version 8* * This command class requires security. Table 7 - Notification Table Alarm Alarm Notification Alarm Reports Description Event type Level Type 0x (01 – Where Alarm level represents user slot Keypad Lock 0x12 0x06 0x05 number max users) 0x(01-max...
Page 20
0x(01-max User was deleted. Alarm level = user slot 0X0D users) number (single) User deleted 0x21 0x06 0X0C 0x00 ¹ All User codes were deleted (all) A Non-Access Code was entered at the 0x(01-max lock. Non-Access 0x26 0x06 0xFE users) Where alarm level represents user slot number 0x00...
Page 21
All Schedule Types 0x(01-max All Schedule Types were Set (erased/set) Erased 0x64 users) for User ID specified in Alarm Level. If 0x06 0xFE Alarm Level = 0xFFFF then all users were affected. All Schedule Types 0x(01-max Schedule(s) has been enable/disabled for 0x65 0x06 0xFE...
Command Class Configuration, Version 4* * This command class requires security. Table 8 - Configurable Parameters Length of Info Configuration Properties Info String (max length Param. allowed Num. Name Length Default is 90) 0x01 (High 0x03 0x01 (High Set Volume Level to high (1), Volume 1 byte Volume)
Page 24
Adjust the time your lock is Shut down 0x0A (10 0x84 (132 0x3C (60 shutdown after reaching its time 1 byte seconds) seconds) seconds) wrong code entry limit. Set the Operating Mode to 0x00 0x03 0x00 Operating normal mode, vacation mode, 1 byte (Normal (Passage...
Page 25
(Auto Relock feature). The Passage Mode feature can only be set when Passage User Pin Code is used to unlock the lock. ³ Additional hardware required. These parameters are only active if the optional Door Position Switch has been installed with the lock.
Command Class Application Status, Version 1 This command class has been implemented per the Z-Wave™ Specification. Command Class Transport Service, Version 2 This command class has been implemented per the Z-Wave™ Specification. Command Class Supervision, Version 1 This command class has been implemented per the Z-Wave™ Specification. Command Class Indicator, Version 3* * This command class requires security.
Page 27
Command Class Basic, Version 2* * This command class requires security. This command class is mapped to Door Lock CC: Table 11 – Basic Mapping Overview Basic Command Door Lock Mapped Command Basic Set (Value) Door Lock Operation Set (Door Lock Mode) Basic Report (Current Value = 0x00) Door Lock Operation Report (Door Lock...