Installation Wiring (Continued)
PoE Door Harness
C
Order of installation may vary. Refer to appropriate sections for instructions.
1. Prop door open.
2. Tape the two lock-side 4-pin connectors to the ring terminal.
3. Using the ring terminal, carefully fish the assembly through the door channel to the lock.
4. Remove tape from ring terminal and door harness connectors.
Hinge-side harness connectors:
4-pin male Molex connector
6-pin male Molex connector with ground wire
Lock-side harness connectors:
Ring terminal
(2) 4-pin connectors
4-pin F
6-pin M
6
A7763B
Drain.Wire
Cable
: CAT 5e,
26 AWG stranded,
shielded, 100ohm
Ring Terminal Secured
to Lock Mounting Plate
Profile Series v.S1 PoE Cylindrical Lock
4-Pin
4-Pin
Ground
PoE.Lock