Parameters/address space
4.1
Measurement types and measuring ranges
The following table shows the measurement types and the respective measuring range.
Table 4- 1
Measurement
type
Current
You can find the tables of the measuring ranges as well as overflow, overrange, etc. in the
Appendix Representation of analog values (Page 71).
4.2
Parameters
Parameters for F-AI 4xI 0(4)..20mA 2-/4-wire HF
Diagnostics functions should be activated or deactivated in accordance with the application,
see section Applications of the F-I/O module (Page 40).
The following parameters are possible:
Table 4- 2
Configurable parameters
Parameters
F-parameters:
Manual assignment of the F-
monitoring time
F-monitoring time
F-source address
F-destination address
F-parameter signature (with-
out address)
20
Measurement types and measuring ranges
Measuring range
0 to 20 mA (2-wire and 4-wire transducer)
4 to 20 mA (2-wire and 4-wire transducer)
WARNING
Value range
Disable
•
Enable
•
1 to 65535 ms
1 to 65534
1 to 65534
0 to 65535
Default
Disable
150 ms
depends on parame-
ter assignment of F-
CPU
suggested by F-
system
calculated by F-
system
Analog input module F-AI 4xI 0(4)..20mA 2-/4-wire HF (6ES7136-6AA00-0CA1)
Resolution
16 bits including sign
16 bits including sign
Parameter reas-
signment in RUN
No
Module
No
Module
No
Module
No
Module
No
Module