IKA C 2000 basic Operating Instructions Manual page 59

Calorimeter system
Table of Contents

Advertisement

3DJH 
1RWH
7KH V\VWHP VDYHV D PD[LPXP RI  FDOLEUDWLRQV SHU GHFRPSRVLWLRQ YHVVHO
DQG PRGH $ PHVVDJH RQ WKH GLVSOD\ LQGLFDWHV ZKHQ WKLV QXPEHU KDV EHHQ
UHDFKHG
,W LV WKHQ QR ORQJHU SRVVLEOH WR VDYH QHZ FDOLEUDWLRQV ,Q WKLV FDVH ROGHU FDOL
EUDWLRQV PXVW EH GHOHWHG PDQXDOO\
%HIRUH GHFRPSRVLWLRQ YHVVHOV FDQ EH GHOHWHG IURP WKH DVVLJQPHQW WR WKH
PHDVXULQJ FHOO WKH FRUUHVSRQGLQJ FDOLEUDWLRQ YDOXHV PXVW ILUVW EH GHOHWHG
2WKHUZLVH LW LV QR ORQJHU SRVVLEOH WR DVVLJQ WKHVH FDOLEUDWLRQ YDOXHV DQG WKH\
ZLOO XQQHFHVVDULO\ WDNH XS VSDFH LQ PHPRU\ 7KHVH FDOLEUDWLRQV FDQ ODWHU EH
UHPRYHG IURP WKH OLEUDU\ RQO\ E\ D VHUYLFH WHFKQLFLDQ
The calibration experiments are listed in the dialog box. The meaning of the col-
umns in the list of experiments is as follows:
g
Use 7DE to place the cursor on 6HO and confirm with 2. or press the  key. You
have thus selected the experiment for calibration. The experiment is marked on the
display with " √ ".
h
Use 7DE and 8S DUURZ to place the cursor on the next experiment and press 6HO.
This will select the next experiment for calibration. The average value of the se-
lected experiments, the average relative error by percent, and the deviation range
(max/min) absolutely and by percentage are displayed in the corresponding fields.
i
Repeat Step 6 for all values that are to be selected. $YHUDJH will then display the
average C value of these experiments.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Evaluation procedure ASTM D1989, D240, D5865, D4809, D5468, E711
For calibration, a dialog reduced to the acid-correction fields and a shortened
results form are displayed. The comments in Section 9.2 under Point } apply
here too.
Evaluation procedure DIN/IKA
In the DIN/IKA evaluation procedure, the acid correction to ASTM D240 or
ASTM D1989 can also be used for calibration. The results form is shortened ac-
cordingly. The other calculation modes are not available for calibrations.
1R
The running number of calibration experiments
& YDOXH
The heat capacity of the calorimeter system determined with the
experiment in question
([SHULPHQW The 6DPSOH QDPH of the relevant experiment
$YHUDJH
Calculated mean value
05)> @
Average relative error (German abbreviation)
0D[0LQ
Deviation range
'LII
The range of deviation as a percentage in reference to the average
value
®
IKA
-WERKE C 2000 basic / control
 (YDOXDWLQJ FDOLEUDWLRQV