Property Boundaries And Transfer Point With Power Storage System - Viessmann Vitovalor PT2 E11T Installation And Service Instructions Manual

Table of Contents

Advertisement

Preparing for installation
Notes on connecting to the mains supply

Property boundaries and transfer point with power storage system

A
B
C
E
F
kWh
Z1
kWh
S1
kWh
S2
H
~
U
V
Fig. 10
Source: VDE AR-N 4105
Low voltage grid
A
Main power supply
B
Domestic distribution box
C
Property boundary
D
Grid operator
E
Customer
F
18
400V / 230V~
D
G
K
L
1~/N/PE
M
kWh
Z2
1~
N
~
O
P
(cont.)
Power distribution
G
On-site consumers
H
Short circuit protection
K
Overload protection, RCD
L
Vitovalor PT2
M
GS protection
N
Inverter (DC/AC converter) S
O
Fuel cell
P
U
Power storage system inverter
Power storage unit
V
S1 Bidirectional power storage management meter
(power storage system standard delivery)
S2 Bidirectional energy management meter (not rele-
vant for billing by the grid operator)
Z1 Balancing bidirectional meter (observe meter cir-
cuit)
Z2 Export meter (standard delivery on Vitovalor PT2)
= 1.5 kVA
EMAX

Hide quick links: