Fault messages for gas condensing module
Fault number
System characteristics
on the display
F.425
System in control mode, cal-
culation out of operation
F.426
Burner in a fault state
F.427
Burner in a fault state
F.430
Connection of automation
modules not possible
F.431
Visualisation and control via
KNX not possible
F.440
Burner locked out
F.441
Burner locked out
F.442
Burner locked out
F.443
Burner locked out
F.444
Burner locked out
F.445
Burner locked out
F.446
Burner in a fault state
F.447
Burner in a fault state
F.448
Burner in a fault state
F.449
Burner in a fault state
F.450
Burner in a fault state
F.451
Burner in a fault state
(cont.)
Cause
Time synchronisation
failed
Short circuit, external un-
lock signal
Lead break, external un-
lock signal
Communication error,
gateway
Communication error KNX Check KNX module connecting ca-
Short circuit, gas pressure
switch at EM-EA1 exten-
sion
Lead break, gas pressure
switch at EM-EA1 exten-
sion
Short circuit, flue gas
damper signal at EM-EA1
extension
Lead break, flue gas
damper signal at EM-EA1
extension
Short circuit, LPG safety
valve (solenoid valve) sig-
nal at EM-EA1 extension
Lead break, LPG safety
valve (solenoid valve) sig-
nal at EM-EA1 extension
Deviation, heat generator
flow temperature sensor
Deviation, ionisation volt-
age signal
Deviation, ionisation cur-
rent signal
Error in scheduled pro-
gram run monitoring
Error in scheduled pro-
gram run monitoring
Error in scheduled pro-
gram run monitoring
Troubleshooting
Measures
Set the time.
Check connection to the burner
control unit.
Reset burner.
Check connection to the burner
control unit.
Reset burner.
Check gateway module connecting
cable and power supply.
ble and power supply.
Check gas pressure switch con-
nections at EM-EA1 extension.
Check gas pressure switch con-
nections at EM-EA1 extension.
Check flue gas damper connection
at EM-EA1 extension.
Check flue gas damper connection
at EM-EA1 extension.
Check solenoid valve connection
at EM-EA1 extension.
Check solenoid valve connection
at EM-EA1 extension.
Check flow temperature sensor of
heat generator. See page 130.
Check ionisation electrode.
Check ionisation electrode.
Check ignition electrodes and con-
necting cables.
Check ionisation electrode and
connecting cable.
Reset burner.
Check ignition electrodes and con-
necting cables.
Check ionisation electrode and
connecting cable.
Reset burner.
Check ignition electrodes and con-
necting cables.
Check ionisation electrode and
connecting cable.
Reset burner.