Viessmann Vitovalor PT2 E11T Installation And Service Instructions Manual page 119

Table of Contents

Advertisement

Fault messages for gas condensing module
Fault number
System characteristics
on the display
F.385
Burner in a fault state
F.386
Burner in a fault state
F.387
Burner in a fault state
F.388
Burner in a fault state
F.391
Burner in a fault state
F.392
Burner in a fault state
F.395
Burner in a fault state
F.396
Burner in a fault state
F.399
Burner in a fault state
F.400
Burner in a fault state
F.401
Burner in a fault state
(cont.)
Cause
Short circuit, signal 1, ioni-
sation current
Lead break, signal 1, ioni-
sation current
Short circuit, signal 2, ioni-
sation current
Lead break, signal 2, ioni-
sation current
Short circuit, flow temper-
ature sensor 2
Lead break, flow tempera-
ture sensor 2
Short circuit, flame tem-
perature signal 1
Lead break, flame temper-
ature signal 1
Short circuit, ionisation
voltage, signal 1
Lead break, ionisation
voltage, signal 1
Short circuit, ionisation
voltage, signal 2
Troubleshooting
Measures
Check ignition electrodes and con-
necting cables.
Check ionisation electrode and
connecting cable.
Reset burner.
Check ignition electrodes and con-
necting cables.
Check ionisation electrode and
connecting cable.
Reset burner.
Check ignition electrodes and con-
necting cables.
Check ionisation electrode and
connecting cable.
Reset burner.
Check ignition electrodes and con-
necting cables.
Check ionisation electrode and
connecting cable.
Reset burner.
Check flow temperature sensor
(see page 130).
Reset burner.
Check flow temperature sensor
(see page 130).
Reset burner.
Check ignition electrodes and con-
necting cables.
Check ionisation electrode and
connecting cable.
Reset burner.
Check ignition electrodes and con-
necting cables.
Check ionisation electrode and
connecting cable.
Reset burner.
Check ignition electrodes and con-
necting cables.
Check ionisation electrode and
connecting cable.
Reset burner.
Check ignition electrodes and con-
necting cables.
Check ionisation electrode and
connecting cable.
Reset burner.
Check ignition electrodes and con-
necting cables.
Check ionisation electrode and
connecting cable.
Reset burner.
119