Commissioning, Inspection and Maintenance
Calibrating the O
Filling the Vacuum Module
Ending Commissioning
Displaying the Menu Structure
Setting the Fuel Supply Times
Matching the Control Unit to the Heating System
68
Probe
2
(with vacuum system)
Vitoligno 300-C Installation/Service
Probe calibration must not be performed during
Note:
commissioning.
The probe calibration required when replacing the
Lambda probe can only be performed manually.
For calibrating the Lambda probe, see page 104.
Press the following keys:
1.
for "Yes"
|/~
"Manual" setting: not possible.
"Automatic" setting:
Suction turbine starts automatically after d is pressed.
Press the following keys:
1.
for "Yes/No"
|/~
If "Yes" is selected: The commissioning sequence
is concluded. The display changes to the standard
menu.
If "No" is selected: Commissioning restarts
2. d to confirm.
If you exit the commissioning sequence by pressing
"å", the structure of the commissioning menu is
displayed. From here, you can switch to the standard
menu by pressing ä.
You can individually select specific times during which
you do not want fuel to be supplied.
Refer to the Vitoligno 300-C Operating instructions.
The control unit must be matched to the system equipment
level. Various system components are recognized
automatically by the control unit and the relevant codes are
set automatically.
Check and adjust all addresses in Coding 1 (see chapter
"Coding 1").
Note: Further setting options are listed in Coding 2.