Repairs
(cont.)
A
Fig. 87
1. Shut off and drain the boiler on the heating water
and DHW sides. See page 127.
2. Pivot the control unit forwards. See page 34.
3. Undo 2 screws
. Pull plate heat exchanger
A
with thermal insulation

Removing the flow sensor

1.
3.
Fig. 88
B
C
B
to the side and lift out.
C
1.
2.
4. Remove thermal insulation
5. Check the connections on the heating water and
DHW sides for contamination and scaling; replace
the plate heat exchanger if necessary.
6. Install in reverse order using new gaskets.