Page 1
VITOLA 200 Hot water heating boiler without low limit 83 to 300 MBH / 24 to 88 kW Technical Data Manual Model Nos. and pricing: see Price List Vitola 200 with Vitoflame Burner and Vitola 200 with Vitoflame Burner, boiler stand Vitocell-H 300 domestic hot water tank and Vitocell-V 300 domestic hot water tank Vitola 200...
H Biferral heat exchanger of cast iron and steel H Straight-forward installation and start-up – for high operational reliability and a long Burners supplied by Viessmann are tested service life. with a combustion analyzer at operating temperature and matched to the boiler H Reduced emissions with the Viessmann input in the factory.
Page 3
Product Information Cut-Away Section Biferral sandwiched heat exchanger surface Viessmann Vitoflame 100 Burner of cast iron and steel offers high operational reliability and a long service life Removable stainless steel Vitotronic 200 – combustion chamber indoor/outdoor digital boiler and heating system control 3”...
1½ Propane burners have same input/output as natural gas burners. Net I=B=R rating based on piping and pick-up allowance of 1.15. Annual Fuel Utilization Efficiency with optional stack damper. Overall dimensions with Viessmann Vitoflame 100 Burner installed. See page 6.
Page 5
Ensure compatibility with chimney system. The chimney vent system must be suitable for the application (low flue gas temperature with possible condensation), see page 10. For information regarding other Viessmann System Technology componentry, please reference documentation of the respective product. "...
Page 6
Technical Data SR/BD 9¾” 2¾” / 250 mm 70 mm Width 4” / 100 mm Overall width Length 6” / 154 mm Overall length VB2-18 to -33=16 ” / 410 mm VB2-40 to -63=17 ” / 448 mm Dimensions Boiler Model inches 30¾...
Page 7
Refer to the following chart to determine Certain boilers (listed with a “z” in the whether support bars are required for your chart) are directly compatible with the For more information see Viessmann Price application. Vitocell-H tank and thus do not require List.
Page 8
This clearance is required for service work. Viessmann strongly recommends maintaining 48” / 1200 mm front clearance on all models. The Vitola 200 can be mounted on a Vitocell-H as shown to reduce the footprint of heating equipment in the mechanical room.
1 carton with boiler control 1 carton with: Vitotronic 300, KW3 Viessmann Vitoflame Burner for multiple temperature heating systems (c/w burner hood and barometric damper) with up to two mixing valves with indoor/outdoor digital boiler and heating...
A 40% antifreeze should be selected. content will provide freeze-up protection to Consult Viessmann with uncertainties in -10°F / -23°C. Do not use antifreeze other Intermediate section regard to a suitable boiler installation...
Installation Examples Important! These examples depict possible piping layouts for Viessmann product equipped with Viessmann System Technology. For boiler and tank combinations, please install only the feasible combinations listed in the Price List. These are simplified conceptual drawings only! Piping and necessary componentry must be field verified.
Page 12
Installation Examples With one low-temperature circuit with 3-way mixing valve, one high-temperature circuit, and with domestic hot water production e.g. with Vitotronic 200, KW2 combined with one Mixing Valve Actuator Accessory Kit Heating circuit Spring-loaded flow check valve Circulation pump Safety header with automatic air vent, pressure relief valve, and...
Page 13
Installation Examples Underfloor heating system with one low-temperature circuit with 3-way mixing valve, and system separation e.g. with Vitotronic 200, KW2 combined with one Mixing Valve Actuator Accessory Kit Heating circuit Spring-loaded flow check valve Circulation pump for heating circuit Safety header with automatic air vent, pressure relief valve, and...
Page 16
Viessmann Manufacturing Company (U.S.) Inc. Viessmann Manufacturing Company Inc. 45 Access Road 750 McMurray Road Warwick, Rhode Island • 02886 • USA Waterloo, Ontario • N2V 2G5 • Canada Tel. (401) 732-0667 • Fax (401) 732-0590 Tel. (519) 885-6300 • Fax (519) 885-0887 www.viessmann-us.com •...
Need help?
Do you have a question about the Vitola 200 and is the answer not in the manual?
Questions and answers