Startup Procedure:

1) Enable the power at the MAIN SERVICE DISCONNECT.
2) Ensure the disconnect handle on the front panel is in the ON Position and that the
EMO button on the front panel is not depressed.
3) Establish purge gas flow.
4) Establish water flow. Allow water to flow for several minutes to ensure all entrapped
air has been purged from the heating column(s).
5) Press the POWER ON switch on the front panel.
6) If all safety components are within allowable ranges, the main load/safety contactor
will engage. The YELLOW indicator light will be illuminated.
7) Verify that the system parameters are correct.
8) Adjust the PROCESS SETPOINT in the OPERATIONS MENU to the desired
temperature.
9) If the unit is being operated for the first time, complete the HEATER CALIBRATION
STARTUP PROCEDURE. This procedure is provided on the following page.
If the unit is not being started for the first time, proceed to step 10.
10) Press the ENABLE HEATERS button on the command panel. The unit will now start
to heat the water.
Note: Steps 8 and 10 can also be accomplished through the remote control interface or
on the ROI. Refer to the REMOTE INTERFACE section of this manual for more
information.