Process Technology LUFRAN Instruction page 28

Fluoropolymer inline water heater
Table of Contents

Advertisement

Wiring (Continued):
In addition to providing incoming power, all high-voltage wiring connections must be
inspected for connections that may have loosened during shipment.
TORQUE SPECIFICATIONS table for proper connection torque values. The torque
table is located on the inside of the front door.
Document Bag for
Electrical Prints,
Control Fuses and
Manual
Opening the front cabinet doors:
1-2 column (24kW – 144 kW) units:
1) Turn the two quarter-turn latches. They are located on the right side of the
door, near the top and bottom.
2) Rotate the disconnect switch handle past the OFF position to the RESET
position and pull the door open.
3-4 column (157 kW – 288 kW) units:
1) Turn the three quarter turn latches on each door. They are located near the
center of the two doors, near the top, middle and bottom.
2) Push the disconnect switch down, past the OFF position to the RESET
position.
3) Hold the switch in the RESET position and open the two doors.
M-43-01
Revision - Date: 08 – 04/06/15
Figure 15: Location of Torque Specifications Label
Torque Specifications Label