Appendix I - Process Technology LUFRAN Instruction

Fluoropolymer inline water heater
Table of Contents

Advertisement

Appendix I

Technician:
Heater Model Number:
Heater Location:
M1
: Liquid Level Sensor, Top Half Plumbing
Procedure
M1-1:
Column #1 Liquid Level
Sensor Inspection
Pass
If sensor fails inspection ─►
Procedure
M1-1:
Column #2 Liquid Level
Sensor Inspection
Pass
If sensor fails inspection ─►
: Inlet/Outlet Process Sensors, Column TC Sensors
M2
Procedure
M2-1:
Inlet Process Sensor Inspection
Pass
If sensor fails inspection ───────────────────────────────►
Procedure
Outlet Process Sensor Inspection
M2-1:
Pass
If sensor fails inspection ───────────────────────────────►
Procedure
M2-1:
Column #1 Sensor Inspection
Pass
If sensor fails inspection ───────────────────────────────►
Procedure
M2-1:
Column #2 Sensor Inspection
Pass
If sensor fails inspection ───────────────────────────────►
M3
: Leak Detector
Procedure
M3-1:
Leak Detector Inspection
Pass
If sensor fails inspection ───────────────────────────────►
: Purge Gas Flow Switch
M4
Procedure
M4-1:
Purge Gas Flow Switch Inspection
Pass
If switch fails inspection ───────────────────────────────►
: Humidistat
M5
Procedure
M5-1:
Column #1 Humidistat Inspection
Pass
If humidistat fails inspection ────────────────────────────►
Procedure
M5-1:
Column #2 Humidistat Inspection
Pass
If humidistat fails inspection ────────────────────────────►
M6
: PRV, Bottom Half Plumbing
Procedure
M6-1:
PRV Inspection
Pass
If PRV fails inspection ────────────────────────────────►
: PRV Sensor
M7
Procedure
M7-1:
PRV Sensor Inspection
Pass
If sensor fails inspection ─►
: Cabinet Cooling Fans
M8
Procedure
M8-1:
Electrical Cabinet Cooling Fan Inspection
Pass
If fan is not moving ──────────────────────────────────►
Procedure
M8-1:
Heater Cabinet Cooling Fan Inspection
Pass
If fan is not moving ──────────────────────────────────►
7010 Lindsay Dr., Mentor, OH 44060 Phone: 440-974-1300 Fax: 440-974-9561 USA/CN: 800-621-1998
LUFRAN MAINTENANCE CHECKLIST
Procedure
M1-2
Done
Procedure
M1-2
Done
Procedure
M7-2
Done
www.processtechnology.com
Heater Serial Number:
: Recalibrated Sensor
If sensor fails recalibration ─►
: Recalibrated Sensor
If sensor fails recalibration ─►
: Recalibrated PRV Sensor
If sensor fails recalibration ─►
Date:
Procedure
M1-3
: Replaced sensor
Done
Procedure
M1-3
: Replaced sensor
Done
Procedure
M2-2
: Replaced sensor
Done
Procedure
M2-2
: Replaced sensor
Done
Procedure
M2-2
: Replaced sensor
Done
Procedure
M2-2
: Replaced sensor
Done
Procedure
M3-2
: Replaced sensor
Done
Procedure
M4-2
: Replaced switch
Done
Procedure
: Replaced humidistat
M5-2
Done
Procedure
M5-2
: Replaced humidistat
Done
Procedure
M6-2
: Replaced PRV
Done
Procedure
M7-3
: Replaced PRV sensor
Done
Procedure
M8-2
: Replaced Fan
Done
Procedure
M8-2
: Replaced Fan
Done