INTRODUCTION (Continued):
While the DAC control system is capable of providing an outlet temperature within 0.3°C
of the desired PROCESS SETPOINT, the maximum possible temperature rise through
the heater is dependant upon the wattage of the unit and the water flow rate through the
unit. The following table illustrates the maximum temperature rise of various models
based upon the water flow rate through the unit.
Flow Rate
L/min
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
The Lufran fluoropolymer inline water heaters include a comprehensive system of safety
controls and devices to insure safe and long-lasting operation. The list of safety devices
includes but is not limited to the following:
EMO pushbutton
Circuit breaker
Ground fault (earth leakage) protection
Pressure relief valve
Liquid level sensors
Leak detector
High process temperature sensors
High element temperature sensors
Purge gas flow switch
Moisture sensors in the purge gas exhaust line
Solid state relay (SSR) fault and overheat detection
Sensor failure (open sensor) detection
M-43-01
Revision - Date: 08 – 04/06/15
Heater Power (Kilowatts)
24
36
52
65
Maximum Theoretical Temperature Rise (°C)
68.6
-
-
-
34.3 51.4 74.3
-
22.9 34.3 49.5 61.9 68.6
17.1 25.7 37.1 46.4 51.4
13.7 20.6 29.7 37.1 41.1
11.4 17.1 24.8 31.0 34.3
9.8
14.7 21.2 26.5 29.4
8.6
12.9 18.6 23.2 25.7
7.6
11.4 16.5 20.6 22.9
6.9
10.3 14.9 18.6 20.6
6.2
9.4
13.5 16.9 18.7
5.7
8.6
12.4 15.5 17.1
5.3
7.9
11.4 14.3 15.8
4.9
7.3
10.6 13.3 14.7
4.6
6.9
9.9 12.4 13.7
4.3
6.4
9.3 11.6 12.9
Figure 2: Maximum Temperature Rise Table
72
105
130
144
-
-
-
-
-
-
-
-
-
-
-
75.0
-
-
60.0 74.3 82.3
50.0 61.9 68.6
42.9 53.1 58.8
37.5 46.4 51.4
33.3 41.3 45.7
30.0 37.1 41.1
27.3 33.8 37.4
25.0 31.0 34.3
23.1 28.6 31.6
21.4 26.5 29.4
20.0 24.8 27.4
18.8 23.2 25.7
- 5 -
210
260
288
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
85.7
-
-
75.0
-
-
66.7
82.5
-
60.0
74.3
82.3
54.5
67.5
74.8
50.0
61.9
68.6
46.2
57.1
63.3
42.9
53.1
58.8
40.0
49.5
54.9
37.5
46.4
51.4
Lufran Single Outlet Manual