Datalog Menu - Process Technology LUFRAN Instruction

Fluoropolymer inline water heater
Table of Contents

Advertisement

Datalog Menu:

This menu allows adjustment of the frequency of datalog sampling. The DAC control
systems will record the following information:
Flow rate (liters per minute)
Outlet Temperature (°C)
Alarm Events
Datalog Menu
Information Panel
TIMER BASE PRESS TO
CHANGE
TIMER VALUE
CURRENT # OF
RECORDS
ENABLE DATALOG
M-43-01
Revision - Date: 08 – 04/06/15
Figure 27: Datalog Menu Screen
This button allows adjustment of the time interval for the data
sampling. Pressing this button will change the time units from SEC
(seconds) to MIN (minutes). Pressing the button again will change
the time units from MIN to HR (hours). Pressing the button a third
time will change the time units from HR back to SEC.
This button allows adjustment of the time period between datalog
events.
This display indicates the number of datalog records that have been
collected. The controller can collect a maximum of 4096 datalogs.
Beyond this, the controller will begin to replace the oldest datalogs
with the new datalogs as they are taken.
This button in the command panel will enable the datalog feature of
the controller. Once enabled, this function button will change to
DISABLE DATALOG.