Some events may only have an activation record (e.g. New Picture, Panic Alarm, Configuration changed).
MicroSD memory card – the control panel uses a microSD card as a memory medium. After connecting
the control panel to a PC using a USB cable two drives will be displayed in the File Manager. FLEXI_CFG
and FLEXI_LOG. The capacity of supplied card can be 2GB, 4GB (SD-HC), or it can be higher. Before you use
brand new SD card perform the control panel reset to get default settings see chapter 12 Reset of the control
panel. And then perform upgrade firmware, see chapter 13 Firmware updates for control panels and other
modules. This procedure save all required files (default texts, voices, etc..) to the SD card.
FLEXI_CFG – with hidden directories and files that contain system settings. Do not alter the contents
of the drive, there is a risk of loss of functionality of the system. This drive also contains the J-Link directory with
the J-Link.exe software, which may be run and used by the System Administrator.
FLEXI_LOG – contains the PHOTO directory and the FLEXILOG.TXT file, where all system events are
recorded. Selected data from the file can be viewed in F-Link / Event History The PHOTO directory is used
to store IMGnnnnn.JPG files that have been sent to the control panel from camera devices (e.g. from motion
detectors with a JA-120PC and JA-160PC camera). Both file types (txt and jpg) are stored in an encrypted form
and their contents cannot be normally viewed with text and picture viewers. Their contents can only be viewed
if the F-Link (J-Link) software is also run in the PC at the same time and the authorization level Service
or Administrator is confirmed by entering of the respective code. Events are recorded in the FLEXILOG.TXT file
up to the size of 10 MB, then the file is renamed to FLEXILOG.OLD and a new file is created.
SIMLock – a function of the control panel that can be activated by the respective ARC on registration
of the control panel to MyJABLOTRON. If this function is activated, then after replacement of the used SIM card
with another one the system will automatically delete the ARC setting (the registration of the system
to MyJABLOTRON will have to be renewed). This step is used to prevent undesired transmission of information
to the ARC from a different card than the one that was registered for it and from which the setting was done.
1.1

Basic system configuration requirements

Mind the requirements of the valid norms when designing the system. The JA-10xK or its variant
the JA-10xKR kit with a radio module can be set to have behaviour according to a pre-set System profile
to comply with all the following conditions (profiles):
1.
Default
2.
EN50131-1, Grade 2
3.
INCERT, Grade 2
In relation to alarm reporting, valid for security grade 2, the control panel has to be installed according to one
of following configurations as a minimum:
At least one siren and an ATS3 class GSM communicator, LAN communicator or PSTN dialler*, or
Two independent communicators for instance GSM + LAN communicator* or GSM + PSTN dialler.
*Caution: Ensure that all LAN devices providing connection to the Internet network have their power backed up!
During system designing it is necessary to take into account splitting into sections and pre-set entrance delays
to be able to set the definition of delay zones. There can be 3 kinds of delayed zones (Delay A, Delay B and
Delay C), each of them has its own timer to pre-set entrance and exit times.
Example: A typical family house with a garage with a perimeter protected by outdoor detectors:
The main gate or entrance gate and also the main door are protected by a magnetic contact. The garage door
and rear door as well. The whole building with perimeter and garage is protected by one section only and
the system keypad is placed at the entrance hall*.
JA-101K(-LAN)(-LAN3G) and JA-106K(-3G)
Security System Control Panels
Factory pre-set profile, all system parameters are optional.
Profile pre-sets some specific system parameters (valid for control panel,
keypads, sirens, etc.) according to the given norm requirements valid for
security grade 2. The parameters can´t be changed.
Profile pre-sets some specific system parameters (valid for control panel,
keypads, sirens, etc.) according to the given norm requirements valid for
security grade 2. The parameters can´t be changed.
7 / 110
Magnet activation and deactivation
Alarm Beginning and End