Keypad backlit indication button - overview of statuses:
Button lights green ON
Button lights yellow ON
Button lights red ON
Button flashes green (2 Hz)
Button flashes yellow (8 Hz)
Button flashes red (8 Hz)
Flashes alternate red/yellow
Flashes alternate green/red
Flashes alternate green/yellow
Button flashes yellow
(2x every 2 sec)
Button flashes red
(2x every 2 sec.)
Button flashes yellow
(1x every 2 sec)
Button flashes red
(1x every 2 sec)
No indication
Keypad control segment optical indication overview:
Segment lights green
Segment flashes green (4 Hz)
Segment lights yellow
Segment lights red
Segment flashes yellow (4 Hz)
Segment flashes yellow (8 Hz)
Segment flashes red (4 Hz)
Segment flashes red (8 Hz)
Segment doesn´t light at all
9.3

System control by remote control

If there is a requirement to control the system before access to the protected premises (arriving by car
at the garage) or building to be protected just by detectors with an instant reaction, it ensures no one can unset
the system from a keypad inside the protected premises (no entrance path), this can be realized by remote
controller before you access the building. It requires the JA-11xR radio module to be enrolled to the system for
communication with wireless devices. It has to be placed at the right place to ensure reliable communication
with the remote in addition to the required working distance.
When using remote controllers (JA-15xJ, JA-16xJ), its buttons behave the same way as the control segments
of a keypad. Every button can control a selected section (the right one always sets and the left one always
unsets). Remote controllers respect rules on how the system should be set from FW 18, so with any obstacles
preventing the setting it will not be possible to set the system.
JA-101K(-LAN)(-LAN3G) and JA-106K(-3G)
Security System Control Panels
Normal operation. Sections controlled from keypad are OK with no faults.
Normal operation and in some of the controlled sections a fault has been
detected. From the LCD keypad menu you can get more detailed
information after user authorization according to their access rights.
If the fault is followed by a rotating Jablotron logo on the LCD keypad it
represents a fault of radio communication between the control panel
and the keypad.
Keypad in BOOT mode, during a FW upgrade.
Authorization performed, the user can change the system status from
segments or browse the menu of the LCD keypad. Authorization time-out
takes 8 sec from the last key pressing or cancel it by pressing ESC.
Unsuccessful setting warning indication
Indication of a currently triggered alarm in a specific section on the keypad.
The type of alarm, name of the section where an alarm has been triggered
and the source of the triggered alarm are visible on the LCD keypad.
Triggered alarm with an active fault
Authorization with alarm memory
Authorization with an active fault
Programming / Service mode. All control segment indication is disabled
for users and the Administrator keypad menu too. The keypad menu is only
available for a service technician until the PC is connected to the control
panel.
Alarm memory indication
Fault indication on keypad in sleep mode (valid for EN50131-1 profile only)
Alarm memory indication on keypad in sleep mode (valid for EN50131-1
profile only)
Keypad in sleep mode
Section status is Unset or PG output OFF.
Entrance delay running and the system waits for authorization to be unset.
Section status is Partially set.
Section status is Set or PG output ON.
System expects authorization when partially set or it reports a fault during
partial setting.
Unsuccessful setting warning indication
System waits for authorization during setting or it reports a problem during
setting.
Alarm memory indication is indicated until it is cancelled.
Service mode or blocked section after alarm.