jablotron JA-101K Manual page 42

Security system control panels
Hide thumbs Also See for JA-101K:
Table of Contents

Advertisement

System control by keypad - procedure:
The system offers a few system profiles which comply with various norm requirements and it also changes the
keypad´s behaviour and of course the method of their control. The system can be controlled in two ways:
1. Variant 1 of system control (valid for all profiles):
Setting the system:
Using variant 1 requires your authorization first becase not all segments have to show their status
according to their settings without authorization!
1. Applying the RFID card / tag or entering the code performs authorization (when a code and card are
both required then their order doesn´t matter).
2. An unset section is indicated by a green LED light on the left segment side.
3. Pressing the red segment button on the right side gives a request for section setting. More requests
can be selected considering the number of used segments.
4. If after a selection the red or yellow LED flashing (8 sec) remains, the system detects an obstacle
preventing the setting (see chapter 9.11 Obstacles preventing setting the system).
5. Successful setting or partial setting is confirmed by red or yellow segment LED lights.
Unsetting the system:
Authorization is required to control the system from a keypad for variant 1!
1. Applying the RFID card / tag or entering a code performs authorization (when a code and card are
both required then their order doesn´t matter).
2. A set section is indicated by a red or yellow LED light on the right segment side. When intrusion
of protected premises is detected it triggers an entrance delay indicated by rapid flashing of
the specific LED.
3. Pressing the green button (or several buttons gradually) on the left side gives a request for section
unsetting.
4. Successful unsetting is confirmed by green segment LED lights.
5. If after unsetting the section the red LED remains rapidly flashing, it indicates the alarm memory
in the section. Cancelling this indication can be performed by further pressing of the green button
on the segment with authorization to cancel this indication or using the LCD keypad menu
and selecting the option "Cancel warning indication".
2. Variant 2 of system control „Default" profile:
Setting the system:
The way of controlling is based on the procedure: "select the required action and authorize yourself". It is
an old style procedure which is not correct for the current norm requirements related to hiding the system
status.
1. An unset section is indicated by a green LED light on the left segment side.
2. Pressing the red segment button on the right side gives a request for section setting. More requests
can be selected considering the number of used segments.
3. If the authorization is required for setting the section, a red (full setting) or yellow (partial setting) LED
indicates the time-out when authorization is expected by slow flashing (8 sec).
4. Applying the RFID card / tag or entering a code performs authorization (when a code and card are
both required then their order doesn´t matter).
5. If after a selection the red or yellow LED flashing (8 sec) remains, the system detects an obstacle
preventing the setting (see chapter 9.11 Obstacles preventing setting the system).
6. Successful setting or partial setting is confirmed by red or yellow segment LED lights.
Unsetting the system:
1. A set section is indicated by a red or yellow LED light on the right segment side. When intrusion of the
protected premises is detected it triggers an entrance delay indicated by rapid flashing of the specific
LED.
2. Pressing the green button (or more buttons gradually) on the left side gives a request for section
unsetting and the segment indicates the time-out when authorization is expected by slow flashing.
3. Applying the RFID card / tag or entering a code performs authorization (when a code and card are
both required then their order doesn´t matter).
4. Successful unsetting is confirmed by green segment LED lights.
5. If after unsetting the section the red LED remains rapidly flashing, it indicates the alarm memory in the
section. Cancelling this indication can be performed by further pressing of the green button on the
segment with authorization to cancel this indication or using the LCD keypad menu and selecting the
option "Cancel warning indication".
JA-101K(-LAN)(-LAN3G) and JA-106K(-3G)
Security System Control Panels
42 / 110
MLJ51410

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ja-106kJa-101k-lanJa-101k-lan3gJa-106k-3g

Table of Contents