Example: to store tel. number 0 123456 to memory no. 2 enter: 7 0 F0 12345 F2
To delete a telephone number enter:
7 F0 Fy
where y is a memory number from 1 to 4
To exit user mode, press the N key.
4.2.2
Telephone communicator testing
Testing is possible in the user mode. To switch the control panel to the user
mode enter F 0 master code. User mode will be indicated by a U on the keypad.
Entering 89 will cause the communicator to send voice message number 2 to all
programmed telephone numbers. It will also send an SMS message if
programmed (see section 0). The telephone line signals will be audible from the
control panel's built in speaker during the test (if the dialer is triggered by an alarm
in normal operation, it will call silently). Testing can be terminated with the N key.
Notify the people who will be called before testing!
To exit user mode, press the N key.

5 System testing

The supervisor should test the system monthly. For testing the control panel
should be in the user mode. Enter F0 master code to switch to the user mode (U
will be indicated on the keypad).
No alarm can be triggered while in the user mode and any triggering of a
detector, a remote control or a panic button will be indicated on the keypad.
Note: some detectors (for example the wireless motion detector) in normal mode can not
send the next triggering information until 5 minutes after the previous triggering was sent. It
is possible to switch such a detector to the testing mode by opening and closing its cover.
See the particular product manual for more details.
If anything does not work during testing, call the installer.
To exit user mode press N.

6 Battery replacement

All the battery-powered items perform regular battery testing. If the lifetime of the
battery is near the end, the system will indicate the need for battery replacement
(Battery indicator and the item address will be shown on the keypad).
When any detector or keypad asks for new batteries, they should be replaced in
a week. To replace batteries either call the installer or do the following:
switch the control panel to the user mode (entering F0 master code)
Alarm system JA-63 „Profi"
- 12 -
MGK51503
Master code
th
Is an extra (15
) access code for the supervisor. It can operate the system and it
also allows for the programming of the other user codes and to enter the user mode
(see section 3).
Factory default master code is 1234. The supervisor should change it after
installation.
Service code
Is an extra code, used by the installer to enter the programming mode. End users
are not usually told this code.
If an invalid access code is entered more than four times in a given period of
time, it will trigger a Tamper alarm on the control panel.
2.1 Arming
On the keypad - enter your user code or press the fast arming button
On the remote control (RC-4x) – press the
system will beep once and the exit delay countdown will start
ARMED indicator will flash during exit delay
you should leave the protected area within the duration of the
exit delay
If there are 4 beeps while arming, the system is indicating an unusual situation
and the keypad will display the specific information:
ALARM and a zone number – the zone is not ready (opened door etc.),
check the indicated item.
b – some detectors are bypassed (done by supervisor, see part 3.5)
Note: supervisor can program an automatic arming for a desired time (for
example, the house will be armed automatically at 21:00 if left disarmed).
Automatic disarming is also programmable. See part 3.4 for details.
*
Fast arming (without access code) can be disabled by the installer
**
The JA-60F battery powered wireless keypad will stop indications 10sec after the most recent key
entry.
Alarm system JA-63 „Profi"
*
.
button
**
- 5 -
MGK51503

Advertisement

loading