15. Basic guidance for installers

1. Create an installation plan that sufficiently covers the building
to be protected.
2. If the customer requests changes to the suggested
configuration, especially reducing the number of detectors,
ask for his request to be given to you in writing to avoid future
disputes.

16. Trouble-shooting

Problem
The control panel is not in service
mode after being powered up.
It is impossible to enroll a wireless
device to the control panel.
The keypad unit indicates a fault
A motion detector triggers false alarms
for no apparent reason.
The wireless keypad does not indicate
entrance delays by beeping.

17. Control panel technical specifications

Power supply
Backup-battery
Backup power output
Number of wireless device addresses
Number of hard-wired inputs
External warning output EW*
Internal warning output IW*
Programmable outputs*
Event memory
Communications frequency (JA-82R)
Security grade
Operating environment
Radio emissions
EMC
Electrical safety
Can be operated according to
* these signals are also transmitted wirelessly to AC and UC receiver
modules.
Jablotron Ltd. hereby declares that the JA-82KRC "OASiS"
control
panel
is
requirements and other relevant provisions of Directive
1999/5/EC. The original of the conformity assessment can
be found on the web site www.jablotron.com, Technical
Support section.
Note: Dispose of batteries safely depending on battery type
and local regulations. Although this product does not contain
any harmful materials we suggest you return the product to
the dealer or directly to the manufacturer after use.
Installation manual: OASiS security system JA-82KRC
Possible causes
The control panel does not have factory-default settings.
The device's location is unsuitable, the control panel antenna is
disconnected, the device's battery was incorrectly installed, the
control panel is not in enrollment mode, the device is too near to
the control panel (it should be at least 2 meters away).
Press the ? key to see the cause.
Animals are moving in the protected area (mice etc), sudden
changes in temperature, significant air movements, movement of
objects having a temperature close to 37°C (e.g. curtains moving
above a radiator)
If the keypad is only battery-powered, then it turns off 20
seconds after the last time a key was pressed. To indicate
entrance delays, first wake it up.
230 V / 50 Hz, max 0.1 A,
CLASS PROTECTION II
12 V,
2.2 Ah, typical battery
lifetime approx. 5 years
maximum continuous load 0.4 A,
intermittent load 1 A for 15 min's
max.
50 (requires a JA-82R module)
4 (or 14 if a JA-82C is plugged
in), double balanced inputs, with
triggering and tamper functions,
programmable
assignment and reactions
switching to GND, max. 0.5A
switching to GND, max. 0.5A
PGX,
PGY
max.
switching
to
programmable function
255 latest events, including date
and time stamping
868 MHz
2 according to EN 50131-1, EN
50131-6, and EN 50131-5-3
II. internal (-10 to +40°C) -
compliant with EN 50131-1
ETSI EN 300220
EN 50130-4,EN 55022
EN 60950-1
ERC REC 70-03
in
compliance
with
the
3. Perform the installation in a very professional and
conscientious manner and always tidy up the site
afterwards.
4. It is very important to teach the end user how to use and test
the system and to check his level of understanding.
5. Get the customer to sign a written statement that the system
was installed according to the customer's specifications and
that the customer understands how to operate the system.
6. Explain the importance of the annual technical inspection of
the system and offer him this service. For more details see
the relevant EN standards.
section
0.1
A,
GND,
essential
21 / 21
Solutions
Reset the control panel.
Check and fix it.
React according to the cause displayed.
Change the location of the detector, select a higher
immunity in the detector, use an optional pet lens in
the detector, program alarms confirmed by two
detectors in the control panel.
Install an ordinary magnetic sensor to the entrance
door, wiring it to the keypad input so that opening
the door wakes up the keypad and reports to the
control panel. Alternatively, power the keypad with
an AC adaptor to prevent sleep mode or install an
indoor wireless siren type JA-80L to generate
entrance delay beeps.