  • Page 3: Table Of Contents

    This manual is valid for control panel model JA-63 version GK61012 (control panel board). The use of Comlink Windows v. 63 software or higher is required for this control panel and can be obtained from our home page at www.jablotron.com JA-63 „PROFI“...
  • Page 4: Architecture Of The Control Panel

    This product should be installed by professional installers. The another JA-6x control panel can be enrolled as a subsystem manufacturer assumes no liability for damages caused by incorrect (Master & Slave architecture). The master control panel receives installation or improper use of this system. information from the sub control panel and it can also arm and disarm the subsystem panel.
  • Page 5: Mains Supply Connection

    Mains supply connection It is specified to connect the control panel by a permanent two- wire cable. The power supply has a double isolation. The ground wire is unattached. RADIO MODULE  An inlet is realized by a permanent two-wire cable with a JA-63R double isolation –...
  • Page 6 (during an alarm, the charging will temporarily halt). The is a back up power output for external items (detectors siren can also be used for arming and disarming chirps etc.). The max. permanent current is 0.4A (1A for max. 15 and as an audible indicator while in the testing mode (see min - not more then one cycle per hour).
  • Page 7: The Ja-60 Keypad(S)

      Back up battery installation The JA-60 keypad(s) There is a space for a size 12V, 1.3 or 2.6Ah battery (battery The system can be programmed and operated by JA-60E size should corresponding to a desired backup period). The keypad(s).
  • Page 8 List of control panel programmable parameters Function sequence options factory note Enrolling of detectors and controllers 1& 7 scroll, 2 erases item R module L1=delay Hard-wired zone input setting nn - zone, x - triggering, 60 nn xys L2=next d. y - reaction, s - section L3=instant L4=tamper...
  • Page 9: Enrollment (Teaching) Of Wireless Items

    has no current communication with any other control panel Enrollment (teaching) of wireless items (This protects you from enrolling your neighbor’s siren). enter: 1  Multiple outdoor sirens or multiple subsystems enrolment – enter 000000 while in enrolling mode. After The control panel equipped with a radio module can enroll up this outdoor sirens and JA-6x subsystems can be enrolled to 32 wireless detectors (2 in each zone), up to 8 controllers...
  • Page 10: Exit Delay

    Note: the control panel also wirelessly transmits the PgX and PgY Exit delay signals. Wireless output modules UC-216 and UC-222 can be used sequence: 2 0 x to receive the signals (see 9.12). The function of the UC module output relays is determined by the 23x and 24x setting. To change the duration of the exit delay enter: 20x (where x represents time in seconds x10).
  • Page 11: Reset Enabled

    9.10 Reset enabled 9.12 Enrollment of the control panel to a UC-2xx or to a master control panel sequence: 2 9 9 sequence: 2 8 x The wireless control panel can send data to output modules The factory default reset (see 11) can be disabled. This way UC–216, UC–222 and UC-260.
  • Page 12: Exit Delay Audible Indication

    9.16 Exit delay audible indication options sequence: 3 3 x 3 7 1 alarm in disarm & partial arming enabled The exit delay can be indicated by the “beeping“ of the 3 7 0 alarm in disarm & partial arming disabled keypad (for the last five seconds, the beeping is faster).
  • Page 13: Only First Source Of Alarm Is Recorded

    9.24 Only first source of alarm is recorded Options 6 9 6 1 Communication loss causes an alarm sequence: 691 x 6 9 6 0 Communication loss causes fault indication When any item triggers the alarm 4 times in a row the system will bypass it until any other events occurs.
  • Page 14: Automatic Arming / Disarming Setting

    9.36 Real time and date setting where nn = number of the enrolled controller from 01 to 08 (c1 to sequence: 4 hh mm dd MM YY The control panel has a built in real time clock. All events are = section: 1 = A, 2 = B stored to the event memory including the time of the event.
  • Page 15: Pc Used With Ja-63

    Note: this procedure resets the factory default settings (see part User can check and operate the JA-63 system easily via their 9). The Master code will be 1234, Service code 6060 and all PC, can read complete events memory with all details, can view user codes, wireless detectors &...
  • Page 16: Recommended Professional In-Staller Basic Rules

    The brief overview you got along with this manual includes the basic assortment of accessories. Jablotron is systematically introducing new and improved items to the market. You can get the most current information from your distributor or you can visit Jablotron’s Internet home page at: www.jablotron.com...
  • Page 17: Control Panel Specifications

    ETSI EN 300220 ** can be operated according to ERC REC 70-03 Hereby, JABLOTRON ALARMS a.s., declares that this JA-63KR is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Original of the conformity assessment can be found at the web page www.jablotron.com, section Technical support.