11.2 Event history:

Event history is accessible in F-Link by pressing of the Events button and selecting "Event history".
In the memory of the control panel (microSD card) up to several millions of records may be stored with
the sequential number, exact date and time and source of the event.
Events from the control panel memory (available also after pressing F8) – approx. 100 kB of events (from
the microSD card) are loaded. If the loading range is insufficient, you can repeatedly select Load / Next
100(500) kB or All. Warning: If you select Load/All, in a control panel with a longer time of operation the loading
may take a few minutes. The history does not record events that occur during service setting (just the opening
and closing of the Service mode is registered). Loaded events can be saved in a file in the File menu using the
Export item (Shft+Ctrl+S), namely in several formats (FDE, PDF, TXT, CSV, XML, HTM or HTML).
The FDE suffix makes it possible for the F-Link to download the events again.
Events online (available also after pressing F7) – in a temporary table all events are recorded that are saved
in the event history and that occur after activation of this option, incl. events during service setting.
Signals online (available also after pressing of F6) – in a temporary table all signals are recorded that are
registered by the BUS (e.g. also activation and deactivation of sensors).
Events from file - events from the event history saved in the FDE database file format can be opened
(see Events from the control panel memory)
Load – makes it possible to load more events deeper from the history by 100 kB, 500 kB (100 kB corresponds
to approx. 1200 events) or all.
Highlight – colour highlighting makes it possible to distinguish event types (alarm with red, control with green,
error with orange, tampering with blue, neutral with light blue, automation or transmissions with grey etc.).
Filter Settings – the filter allows you to obtain only desired information by time, by event type, sections, users,
devices or PG outputs in a very detailed way. Filters can be combined to increase searching efficiency in deep
history.