jablotron JA-63 User Manual
Hide thumbs Also See for JA-63:

Advertisement

JA-63 „Profi"
User manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JA-63 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for jablotron JA-63

  • Page 1 JA-63 „Profi“ User manual...
  • Page 2: Table Of Contents

    Enrollment of the control panel to UC-2xx modules ............... 13  1 Limited warranty Subject to the conditions of this Limited warranty Jablotron Ltd. warrants this product to be free from defects in design, material and workmanship at the time of its original purchase by a customer for a subsequent period of two (2) years.
  • Page 3: Indicators

    (Tamper, Failure or Battery) Wireless siren was caused by the outdoor wireless siren Sub control indicated event (Alarm, Tamper, Failure or panel Battery) was caused by the sub control panel Alarm system JA-63 „Profi“ - 3 - MGK51504...
  • Page 4: Controlling The System

    Central monitoring station and can also be viewed using a PC with Comlink software. All user codes are empty as a factory default and should be programmed by the supervisor (see section 4.2). Alarm system JA-63 „Profi“ - 4 - MGK51504...
  • Page 5: Arming

    Automatic disarming is also programmable. See part 4.4 for details. Fast arming (without access code) can be disabled by the installer The JA-60F battery powered wireless keypad will stop indications 10sec after the most recent key entry. Alarm system JA-63 „Profi“ - 5 - MGK51504...
  • Page 6: Disarming

    If user does not stop the alarm, it will stop automatically after the programmed period and the alarm memory indicator will activate. The control panel will return to the same mode as before the alarm. Alarm system JA-63 „Profi“ - 6 - MGK51504...
  • Page 7: Home Arming

    Entering F1 master code will control only section A and F2 master code only section B (this is true only when fast arming is disabled by the installer). Note: partial Home arming is not possible if the system is split. Alarm system JA-63 „Profi“ - 7 - MGK51504...
  • Page 8: Subsystem Arming

    Subsystem arming In a large building a sub control panel can be enrolled to the JA-63. The subsystem reports all alarms and failures to the main system. The installer can program if the systems will be armed and disarmed separately (by their own codes and remote controls) or if the main control panel will rule the sub control panel.
  • Page 9: User Codes Setting

    = hours; mm = minutes; DD = day; MM = month and YY = year Example: at 21:30 on March 19. 2005 enter: 4 21 30 19 03 04 To exit user mode press N. Alarm system JA-63 „Profi“ - 9 - MGK51504...
  • Page 10: Automatic Arming / Disarming

    2 for 2 seconds to bypass the source for the next arming period (confirmed by flashing Battery LED); b. or press key 3 for 2 seconds to bypass the source permanently (confirmed by the Battery LED being permanently lit); Alarm system JA-63 „Profi“ - 10 - MGK51504...
  • Page 11: Digital Communicator

    Note: enter a pause (F0) after the last digit of a number, which is calling a mobile phone. This way the number will be called only once and the dialer will not check the line signals (some mobile phone systems do not generate standard telephone line signals). Alarm system JA-63 „Profi“ - 11 - MGK51504...
  • Page 12: Telephone Communicator Testing

    When any detector or keypad asks for new batteries, they should be replaced in a week. To replace batteries either call the installer or do the following:  switch the control panel to the user mode (entering F0 master code) Alarm system JA-63 „Profi“ - 12 - MGK51504...
  • Page 13: Enrollment Of The Control Panel To Uc-2Xx Modules

    8 Enrollment of the control panel to UC-2xx modules The wireless control panel can send data to UC–216, UC–222 and UC-260 output modules. To enroll the JA-63 control panel to the UC-2xx:  switch the control panel to the user mode (entering F0 master code) ...
  • Page 14 User codes and controllers section code user name notes index Master code - supervisor Telephone communicator setting memory calling to tel. number notes Pager Timers exit delay entrance delay alarm duraton Notes: Alarm system JA-63 „Profi“ - 14 - MGK51504...
  • Page 15 Detectors section detectors position location in the house reaction* type I – instant D – delayed F – fire P – panic T – tamper N – next delayed Alarm system JA-63 „Profi“ - 15 - MGK51504...
  • Page 16 Notes: Alarm system JA-63 „Profi“ - 16 - MGK51504...