  • Page 1 Security Alarm Control Panel HESTIA-915 installation manual...
  • Page 2: Specifications

    Description: The Hestia-915 is the next generation in versatile wire operated alarm systems. The control panel provides eight protection zones: FIRE, TAMPER and six programmable loops. All loops are balanced with End Of Line resistors. Most control panel functions are programmable, resulting is a very flexible system. Control panel is offered in different housing options (H-915C - plastic housing with built in keypad &...
  • Page 3 2 ARM - (Yellow, Green and Red LEDs) if this LED is off, the system is disarmed. If it is yellow and slowly blinking, it indicates an Exit delay. A continuously lit yellow LED indicates that the system is fully armed. A Rapidly blinking yellow LED indicates an Entrance delay.
  • Page 4: Procedure For Turning On The Power

    15VAC - these terminals are for A.C. power supply connection. Use a transformer with 15VAC output (min. 20VA), or you can use the Jablotron PSU-10 adapter. This input is protected by a FU1 (1.6A) fuse. Do not switch the power on before the installation is finished! ACCU.
  • Page 5: Installer Code

    INSTALLER CODE A default installer code 1010 is programmed into the H-915. This code is used with the [∗] [6] command to enter the installer programming level. This code can be changed by installer. ARMING Enter a valid access code to arm. Arming is confirmed by the ARM LED and with one beep from the keypad's buzzer. The system can not be armed if any zone is triggered.
  • Page 6: Commands List

    [∗] COMMANDS LIST All the commands bellow can be used only when the control panel is in the standby mode and is disarmed. [∗] [0] - Quick arming . You can use this command instead of your access code to arm the system. It can be used only for arming, not for disarming.
  • Page 7: Installer Programming

    INSTALLER PROGRAMMING Press [∗] [6] [INSTALLER CODE] to enter installer programming level (factory default installer code is 1010). It can only be done while the panel is disarmed. Entering the programming level is confirmed by the ERROR LED permanently lighting. While in this level, no zone can trigger an alarm in.
  • Page 8 x=0 Technical alarm - results when the a.c. power is off for a long time and the backup battery is nearly discharged. Any combination of outputs can be selected for this kind of alarm (y can be from 0 to 7) x=1 Fire alarm - triggered by a fire loop.
  • Page 9 y= 0 relay 1 ext. siren 2 panic 3 fire 4 arm 5 int. siren ∗ Note: If an output is activated by the [5][xy] command, the output will stay active until you press [ ]. Then you are back in the installer programming level again.
  • Page 10: Installer Programming Work Sheet

    INSTALLER PROGRAMMING WORK SHEET: Press [∗] [6] [Installer Code] to enter installer programming level. The [#] must be pressed to exit programming level. Fill out the following tables and use them as guide when programming. [0] [xxxx] New Installer Code default programmed 1010...
  • Page 11 USER’S OPERATION GUIDE OF H-915 Zone location No.: protected area zone type Tamper: Fire: Exit: Entry: Alarm: if troubles, call your installer phone: H-915 installation manual 11/11 TBT502 01...
  • Page 12 H-915 installation manual 11/12 TBT502 01...