Operating/programming the system by PC

The OASiS system can be operated and programmed locally using a PC
running OLink software. To connect the control panel to the PC use a
JA-80T, JA-82T interface or a JA80-BT wireless Bluetooth interface.
OLink software can be used by installers and end users. The software
only allows access to features allowed by the access code (service or user).
If the control panel is equipped with a suitable communicator such as the
JA-80Y (GSM/GPRS) or JA-80V (LAN/telephone line) then the system can
also be accessed from a PC connected to the Internet. For this remote
access it is first necessary to register at www.GSMLink.cz or directly by Olink
v. 2,0 and higher (JA-82Y only).

10 Trouble-shooting

Problem
The control panel is not in service
mode after being powered up.
It is impossible to enroll a wireless
device to the control panel.
The keypad unit indicates a fault
A motion detector triggers false alarms
for no apparent reason.
The wireless keypad does not indicate
entrance delays by beeping.
JA-83K control panel installation manual
Possible causes
The control panel does not have factory-default settings.
The device's location is unsuitable, the control panel antenna is
disconnected, the device's battery was incorrectly installed, the
control panel is not in enrollment mode, the device is too near to
the control panel (it should be at least 2 meters away).
Press the ? key to see the cause.
Animals are moving in the protected area (mice etc), sudden
changes in temperature, significant air movements, movement of
objects having a temperature close to 37°C (e.g. curtains moving
above a radiator)
If the keypad is only battery-powered, then it turns off 20
seconds after the last time a key was pressed. To indicate
entrance delays, first wake it up.
fig. 15 Trouble-shooting
9

Basic guidance for installers

Create an installation plan that sufficiently covers the building to be
protected.
If the customer requests changes to the suggested configuration in
order to reduce the price, especially reducing the number of detectors,
ask for his request to be given to you in writing. (You will avoid future
disputes if the insufficient protection is overcome by intruders.)
Perform the installation in a very professional and conscientious
manner and always tidy up the site afterwards.
It is very important to teach the end user how to use and test the
system and to check his level of understanding.
Get the customer to sign a written statement that the system was
installed according to the customer's specifications and that the
customer understands how to operate the system.
Explain the importance of the annual technical inspection of the system
to the customer and offer him this service. For more details see the
relevant EN standards.
For further information see EN 50131-1 and other standards.
Reset the control panel.
Check and fix the mentioned problems.
React according to the cause displayed.
Change the location of the detector, select a higher
immunity in the detector, use an optional pet lens in
the detector, program alarms confirmed by two
detectors in the control panel.
Install an ordinary magnetic sensor to the entrance
door, wiring it to the keypad input so that opening
the door wakes up the keypad and reports to the
control panel. Alternatively, power the keypad with
an AC adaptor to prevent sleep mode or install an
indoor wireless siren type JA-80L to generate
entrance delay beeps.