Exhaust Setup And Balancing - Bravo 8105 Installation Manual

Convection reflow system
Table of Contents

Advertisement

Exhaust Setup and Balancing

Introduction
Location Description
Photograph
Procedure
2-9317-370-00-0
It is important that the exhaust to the Bravo™ 8105 is properly connected and
balanced. Use a manometer or similar measuring device to ensure adequate
exhaust when making the facility connections.
The exhaust measuring points, blast gates and connections are located at the rear
of the Bravo™ 8105 behind the upper access panels.
Remove the panels by using an ordinary straight–slot screwdriver to turn the
screws 1/4 turn clockwise to release the panels.
Figure 2–27 depicts the exhaust ductwork located in the rear of the Bravo™ 8105
behind the upper rear access panels.
Figure 2–27
ATTENTION
Standard exhaust duct may be used on the external exhaust. It is not necessary
to attach flexible tubing to the external exhaust port unless desired.
Ensure that a functioning exhaust is attached to the rear external exhaust port of
the Bravo™ 8105.
• Open all blast gates.
• Open or close the blast gates by moving the control arms secured by the wing
nuts. Refer to Figure 2–28.
Bravo™ 8105 Installation Guide
B R A V O ™ 8 1 0 5 M A C H I N E I N S T A L L A T I O N
Exhaust Setup and Balancing
2-57