Bravo 8105 Installation Manual page 58

Convection reflow system
Table of Contents

Advertisement

B R A V O ™ 8 1 0 5 M A C H I N E I N S T A L L A T I O N
2
Power Connection
Photograph
Procedure (Continued)
2-48
Figure 2–20
4. Once the tabs are removed, route the power lines through the entry point to
the switch. There are three (3) hex lug connectors on the bottom of the
switch, and a ground connector located in the cabinet. Refer to B in Figure 2–
21.
5. Connect the ground line to the yellow and green ground connector. The
ground line connects into a hex lug connector. Secure the connector with a
6mm allen wrench. Refer to A in Figure 2–21.
6. Next connect the power line to SW01. Connect the lines so that they enter
the hex lug connector from the back of the switch.
7. Tighten the hex lug connectors with an appropriately–sized allen wrench.
8. Return the insulator tabs that were removed in Step 3 into the bottom of the
switch insulator plate.
Bravo™ 8105 Installation Guide
Tab slides out of plate
Rev. 2

Advertisement