Photograph
Verify Machine Voltage
2-9317-370-00-0
A
Ground
Connector
B
SW01 Inside
(Power Connection)
C
Power Inlet (Inside)
Figure 2–21
Electrical Hazard
The following voltage check exposes personnel to dangerous voltage levels. The
procedure is only to be performed by adequately trained personnel.
Check the Voltage at the L connectors at CON01 inside the power cabinet. The
voltage between any two (2) L connectors (i.e., L1 and L2, L2 and L3 or L1 and
L3) should be approximately the same value that was measured at facility
voltage. Note that it is a phase–to–phase measurement (not phase–to–ground).
Bravo™ 8105 Installation Guide
B R A V O ™ 8 1 0 5 M A C H I N E I N S T A L L A T I O N
Power Connection
2-49