Optics Removal; Switch Power-Up - Dell EMC PowerSwitch S4100-ON Series Installation Manual

Table of Contents

Advertisement

Platform
S4128T-ON
S4148T-ON
S4148U-ON
For a list of supported optics, see the S4100-ON Series data sheet at
CAUTION:
ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap
when handling the S4100-ON Series and its components.
WARNING:
When working with optical fibers, follow all warning labels and always wear eye protection. Never look directly into
the end of a terminated or unterminated fiber or connector as it may cause eye damage.
1
Position the optic so it is in the correct position.
The optic has a key that prevents it from being inserted incorrectly.
2
Insert the optic into the port until it gently snaps into place.
NOTE:
When you cable the ports, be sure not to interfere with the airflow from the small vent holes above and below
the ports.

Optics removal

Remove an optic by pushing the tab on the optic and sliding the optic from the port.
When removing optics with direct attach cables (DACs) from the port, pull the release tab firmly and steadily. Before pulling the release tab,
you may need to gently push the optic into the port to ensure that it is seated properly. Do not jerk or tug repeatedly on the tab.

Switch power-up

Supply power to the S4100–ON Series (S4128F-ON, S4148F-ON, S4148FE-ON, S4128T-ON, S4148T-ON, and S4148U-ON) switch after
you mount it in a rack or cabinet.
Dell EMC recommends reinspecting your switch before powering up. Verify the following:
The equipment is properly secured to the rack. Dell EMC recommends properly grounding the switch.
The ambient temperature around the unit, which may be higher than the room temperature, is within the limits specified for the S4100–
ON Series, see Specifications.
There is sufficient airflow around the unit.
The input circuits are correctly sized for the loads and that you use sufficient overcurrent protection devices.
All protective covers are in place.
Blank panels are installed if you do not install optional modules.
Description
2 fixed QSFP+ optical ports
2 fixed unified QSFP28 optical ports
2 fixed QSFP28 optical ports
28 fixed 10GBase-T RJ-45 optical ports
2 fixed QSFP28 optical ports
48 fixed 10GBase-T RJ-45 optical ports
2 fixed QSFP+ optical ports
4 fixed QSFP28 optical ports
24 fixed unified Fibre channel or Ethernet SFP+ optical ports
24 fixed Ethernet SFP+ optical ports
2 fixed Ethernet QSFP+ optical ports
4 fixed unified Fibre channel or Ethernet QSFP28 optical ports
www.dell.com/support
or contact your Dell EMC representative.
S4100–ON Series installation
33