Optics removal

Remove an optic by pushing the tab on the optic and sliding the optic from the port.
When removing optics with direct attach cables (DACs) from the port, pull the release tab firmly and steadily. Before pulling the release
tab, you may need to gently push the optic into the port to ensure that it is seated properly. Do not jerk or tug repeatedly on the tab.

Switch start up

Supply power to the Z9332F-ON switch after it is mounted in a rack or cabinet.
Dell EMC recommends reinspecting your switch before powering it up. Verify the following:
Optional: The equipment is properly secured to the rack and properly grounded.
Optional: The equipment rack is properly mounted and grounded.
The ambient temperature around the unit, which may be higher than the room temperature, is within the limits that are specified for
the Z9332F-ON switch.
There is sufficient airflow around the unit.
The input circuits are correctly sized for the loads and that you use sufficient overcurrent protection devices.
CAUTION:
Do not start up the switch if a fan module is not installed.
NOTE:
A US AC power cable is included for powering up an AC power supply. You must order all other power cables
separately.
NOTE:
ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap
when handling the Z9332F-ON switch and components.
Start up sequence
When the switch powers up, the fans immediately come on at high speed. The fan speed slows as the switch continues to boot.

After switch placement

After you have securely installed and powered on the Z9332F-ON switch:
For OS10 Networking operating system documentation and resources, see the
For ONIE documentation and resources, see www.onie.org.
NOTE:
If necessary, to upgrade your software or firmware images, go to the
switch at www.dell.com/support.

Switch replacement

The following steps describe removing and replacing a switch with an identical replacement switch. For further assistance when replacing
a switch, contact your Dell EMC support representative.
NOTE:
Some steps do not apply if you are replacing a different switch or non-Dell EMC switch.
NOTE:
ESD damage can occur when components are mishandled. Always wear an ESD-preventive wrist or heel ground
strap when handling the switch and accessories. After you remove the original packaging, place the switch and
components on an anti-static surface.
1. Back up the switch configuration to your back-up computer or laptop TFTP server.
OS10# copy config://startup.xml config://<backup file name>
2. Disconnect the power source.
3. Label and remove all cables.
4. Remove the switch from the rack.
At the same time, press in the two side-release bars on the switch and slide the switch forward.
20
Z9332F-ON switch installation
Dell EMC Networking OS10 Info
Drivers and Downloads page for your
Hub.