Storing Components - Dell EMC PowerSwitch S4100-ON Series Installation Manual

Table of Contents

Advertisement

CAUTION:
Always disconnect the power cable before you service the power supply slots. The switch has multiple power cords.
Before servicing, ensure all power cords are disconnected.
CAUTION:
On an AC switch, use the power supply cord as the main disconnect device. Ensure that the socket-outlet is located
and installed near the equipment and is easily accessible.
NOTE:
Module power is software controlled. You do not see module LEDs when the switch powers up in ONIE.

Storing components

If you do not install your S5200F-ON Series switch and components immediately, properly store the switch and all components using these
guidelines:
Storage location temperature must remain constant. The storage range is from -40°C to 70°C (-40° to 158°F).
Store on a dry surface or floor, away from direct sunlight, heat, and air conditioning ducts.
Store in a dust-free environment.
NOTE:
ESD damage can occur when components are mishandled. Always wear an ESD-preventive wrist or heel ground strap
when handling the S5200F-ON Series switch and accessories. After you remove the original packaging, place the S5200F-ON
Series switch and components on an anti-static surface.
Site preparations
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents