Section 7

During Cleaning and Sanitizing

ALWAYS FOLLOW LOCAL HEALTH CODES.
Cleaning and sanitizing schedules are governed by your
state or local regulatory agencies and must be followed
accordingly.
Please consult your governing food code to determine
the maximum number of days allowed between 
brush-clean cycles.
The following checkpoints should be stressed during the
cleaning and sanitizing operations.

Troubleshooting Bacterial Count

Thoroughly clean and sanitize the machine
regularly, including complete disassembly and
brush-cleaning.
Use all brushes supplied for thorough cleaning.
The brushes are specially designed to reach all
mix passageways.
Use the white bristle brush to clean the mix inlet
hole which extends from the mix hopper down to
the rear of the freezing cylinder.
Use the black bristle brush to thoroughly clean the
rear shell bearing at the rear of the freezing
cylinder, and the drive hub opening in the rear wall
of the mix hopper. Use a generous amount of
cleaning solution on the brush.
Properly prepare the cleaning and sanitizing
solutions. Read and follow the label directions
carefully. Too strong of a solution may damage
the parts, and too weak of a solution will not do an
adequate job of cleaning or sanitizing.
The temperature of the mix in the mix hopper and
walk-in cooler should be below 40°F (4.4°C).
Discard remaining mix from the freezer during
"Cleaning Procedures."
Operator's Checklist
Operator's Checklist

Regular Maintenance Checks

Replace scraper blades that are nicked or
damaged. Before installing the beater assembly,
make sure the scraper blades are properly
attached to the beater assembly.
Check the rear shell bearing for signs of wear
(excessive mix leakage in drip pan) and make
sure it is properly cleaned.
Using a screwdriver and cloth towel, clean the
rear shell bearing and the female hex drive socket
of lubricant and mix deposits.
Dispose of O-rings and seals if they are worn,
torn, or fit too loosely, and replace them with new
ones.
Follow all lubricating procedures as outlined in
"Assembly" on page 6-1.
If your machine is air-cooled, check the
condensers for dirt and lint. Dirty condensers will
reduce the efficiency and capacity of the machine.
Condensers should be cleaned monthly with a
soft brush. Never use screwdrivers or other metal
probes to clean between the fins.
Note: For machines equipped with an air filter, it
will be necessary to vacuum-clean the filters
monthly.
WARNING! Always disconnect electrical
power prior to cleaning the condenser. Failure to follow
this instruction may result in electrocution.
If your machine is water-cooled, check the water
lines for kinks or leaks. Kinks can occur when the
machine is moved back and forth for cleaning or
maintenance. Deteriorated or cracked water lines
should be replaced only by an authorized Taylor
distributor.
Model C708 - WAWA