OPERATING PROCEDURES
10. Secure the pump parts in position by sliding the
retaining pin through the cross holes located at the
bottom of the pump cylinder. (See Figure 6-29.)
Note:
When the pump is correctly installed, the head of
the retaining pin should be facing up.
11. Install one O-ring on each end of the mix feed tube
and thoroughly lubricate. (See Figure 6-30.)
6
12. Slide the large O-ring and two small O-rings into the
grooves on the pump driveshaft. Thoroughly lubricate
the O-rings and the shaft. Do not lubricate the hex
end of the shaft. (See Figure 6-31.)
6-8
Figure 6-29
Apply the appropriate
Taylor approved food safe lubricant.
Figure 6-30
15008
13. Install the hex end of the driveshaft into the drive hub
at the rear wall of the mix hopper. (See Figure 6-32.)
15170
Note:
To ease installing the pump, put the ball crank of
the driveshaft in the 3 o'clock position.
14. Lay the agitator, pump assembly, pump clip, mix feed
tube, and locking clip in the bottom of the mix hopper
for sanitizing. (See Figure 6-33.)
Model C708 - WAWA
Apply the appropriate
Taylor approved food safe lubricant.
Figure 6-31
Figure 6-32
Figure 6-33
Operating Procedures
15009
12012
12284