Taylor Wawa C708 Operator's Manual page 22

Heat treatment soft serve freezer
Hide thumbs Also See for Wawa C708:
Table of Contents

Advertisement

USER INTERFACE
When the power switch is placed in the ON position, the
control panel keys become operative. The LCD will either
be blank or indicate that the machine has been cleaned.
UNIT CLEANED
International Models Only
Some international models will continuously display the
temperature of the mix hopper when the power switch is
in the ON position.
HOPPER
UNIT CLEANED
If the control is set for international configuration, the
following screen will appear when the Heat key is
pressed.
5
ARE YOU SURE?
>
Yes
No
Use the Up or Down arrow key to move the cursor to
"Yes". Press the SEL key to immediately start a Heat
cycle.
Note:
The machine must be in Auto or Standby mode
and have sufficient mix in the hopper before the machine
can successfully enter the Heat mode of operation.
Heat Cycle
The Heat key on the control panel is illuminated
throughout the Heat Treatment cycle. Two warning
messages will be displayed on the screen. DO NOT
DRAW will be displayed when the mix temperature is
below 130°F (54.4°C).
DO NOT DRAW
5-4
21.0
Model C708 - WAWA
When the temperature of the mix is above 130°F
(54.4°C), the screen will display the message HOT
PRODUCT, indicating that hot product is in the machine.
HOT PRODUCT
WARNING! DO NOT attempt to draw product or
disassemble the machine during the Heat Treatment
cycle (if equipped). The product is hot and under extreme
pressure. Severe burns from hot product may result if this
instruction is not followed.
In the Heat cycle, the mix temperature in the hopper and
freezing cylinder must be raised to 151°F (66.1°C) within
90 minutes.
When the heating phase is complete, the freezer goes
into the holding phase of the cycle. The holding phase
will keep the temperature above 151°F (66.1°C) for a
minimum of 35 minutes.
The final phase of the Heat Treatment cycle is the cooling
phase. The freezer must cool the mix below 41°F (5°C)
within 90 minutes.
When the entire Heat cycle has been completed, the
Heat key will no longer be illuminated. The machine will
enter the Standby mode (Standby key illuminates). The
machine can be placed in Auto mode or left in Standby
mode.
To comply with health codes, heat treatment system
freezers must complete a Heat Treatment cycle daily
and must be disassembled and brush-cleaned according
to the frequency specified by your federal, state, or local
regulatory agencies. Please consult your governing food
code to determine the maximum number of days allowed
between brush-cleaning cycles.
Brush-cleaning is the normal disassembly and cleaning
procedure found in the Operator's Manual. Failure to
follow these guidelines will cause the control to lock the
freezer out of the Auto mode.
If the Heat Treatment cycle fails, the screen will display a
failure message and return the freezer to the Standby
mode.
User Interface