User Guide - Beretta EXCLUSIVE C Installer And User Manual

Hide thumbs Also See for EXCLUSIVE C:
Table of Contents

Advertisement

Available languages

Available languages

USER GUIDE

Depending on the type of application, some of the functions described in this manual might not be available.
6
CONTROL PANEL REC10
The REC10 remote control unit has the function of a machine
interface, as it displays the system's settings and allows the
parameters to be accessed.
It is also capable of providing multi-zone control and weekly room
thermostat functionality.
While the system may be equipped with multiple REC10 units,
ONLY ONE serves as the machine's interface (MASTER). The other
REC10 units serve as a chronothermostat for regulating the ambient
temperatures of the zones with which they are associated; in this
latter case, the main screen of the REC10 shows the environmental
data of the zone to which it is related.
The REC10 unit features a backlit liquid crystal display.
LED
REC10
Key area
On the left and right sides are displayed the icons indicating the status of the system, their meaning is the following:
This icon indicates that the OFF operating status mode has been set. Each ignition request is ignored except for the anti-freeze function. The
pump anti-lock, 3-way valve and anti-freeze function remain active.
This icon indicates that WINTER mode has been selected (HEATING function enabled). If a heating request from the main zone is in progress,
the icon will be flashing.
This icon indicates that the circuit for domestic hot water production is enabled. When a domestic hot water request is in progress, the icon
flashes. The P at the top of the domestic hot water icon indicates that the boiler preheating function is enabled; the P when flashing indicates
that a preheating request is in progress.
When the "central heating programming timing" is enabled this icon indicates that the system heating (main zone) is in AUTOMATIC mode (the
management of the heating requests follows what has been set with the timer).
If the heating function is not enabled during the current time frame, the icon will be crossed out.
When the "central heating programming timing" is enabled this icon indicates that the system heating (main zone) is in MANUAL mode (the
management of the heating requests does not follow what has been set with the programming timing, but it is always active).
OFF
This icon indicates that the system (main zone) has been set to off (not active).
This icon indicates that the system is detecting the presence of a flame.
This icon indicates the presence of an anomaly, and is always flashing.
Note:
The temperature of the hot water probe is shown at the centre of the main screen. The value's meaning is indicated at the bottom of the display.
Whenever a heating request is in progress, the value displayed at the centre of the screen refers to the system's flow sensor, with the relative indication.
The value expressed in bar refers to the system's water pressure.
The top of the screen shows the current date and time, as well as the outdoor temperature, if available.
Light signal indicating the operating status of the boiler. Can be red or green (see specific paragraph)
Boiler control panel
ok=
confirm
back= return to the previous screen
cancel selection
return to the main screen (press > 2 sec.)
up=
allows you to choose between the options PLANT-STATE-SET-INFO-MENU and to surf through the
submenus scrolling upwards
down= allows you to choose between the options PLANT-STATE-SET-INFO-MENU and to surfe through the
submenus scrolling down
FRI
FRI
PLANT
PLANT
18/05/2013
12:17
1.3 bar
MENU
MENU
STATE
STATE
42
°C
P
INFO
INFO
SET
SET
HOT WATER TEMPERATURE
HOT WATER TEMPERATURE
REC10
ENGLISH
LED
35

Advertisement

Table of Contents
loading

Table of Contents