Beretta EXCLUSIVE C Installer And User Manual page 54

Hide thumbs Also See for EXCLUSIVE C:
Table of Contents

Advertisement

Available languages

Available languages

EXCLUSIVE
MENIU
SETĂRI
ORA ŞI DATA
LIMBĂ
RETROILUMINARE
PROGRAM ORAR
PRINCIPALĂ
ZONA1
ZONA2
ACM
POMPĂ DE CĂLDURĂ ACM
DATE TEHNICE
INSTALARE
MANAGER ZONE
MODIFICARE ZONĂ
TIP SOLICITARE
ADRESĂ BE16
CONF HIDRAULIC
TIP ZONĂ
SETARE MIN. ÎC
SETARE MAX. ÎC
MODIFICARE NUME
PI - PROPORŢIONAL
PI - INTEGRAL
ACŢIONARE VANĂ
ÎNCHIDERE LA PORNIRE
EVACUARE TERMINATĂ
EVACUARE TERMINATĂ TIMP
TESTARE
EVACUARE TERMINATĂ TIMP
AŞTEPTARE
EVACUARE TERMINATĂ
TIMP REPAUS
TEMP PROT ANTIÎNGHEŢ
TEXT PROT ANTIÎNGHEŢ
POR
ADĂUGARE ZONĂ
ŞTERGERE ZONĂ
CALIBRARE SENZOR
RESETARE SISTEM
54
VALOARE IMPLICITĂ
SETATĂ DIN FABRICĂ
TIP ACŢIONARE
ZONĂ DIRECTĂ
TEMP. ÎNALTĂ
ZONĂ COMPENSARE PROT
ANTIÎNGHEŢ
0 (1 dacă REC10 este setat
la temperatura AMBIANTĂ)
VALOARE
MINIMĂ
ROMÂNĂ
5 min
1 min
PRINCIPALĂ
PRINCIPALĂ / ZONA1 / ZONA2
ITRF05/AKM
ITRF05/AKM
TERMOSTAT / SONDĂ TEMPERATURĂ /
TERMOSTAT
REC10 PRINCIPAL / REC10 SECUDAR
- -
1
ZONĂ DIRECTĂ
TEMP. ÎNALTĂ
40 °C (AT)
20 °C
20 °C (BT)
80,5 °C (AT)
SETARE MIN. ÎC
45 °C (BT)
5
0
10
0
120 sec
0 sec
140 sec
0 sec
55 °C
0 °C
0 min
0 min
2 min
ACŢIONARE VANĂ
2 min
0 min
6 °C
-20 °C
5 °C
1 °C
10 °C
0 °C
0
- 6,0 °C
0,0 °C
VALOARE
NOTE
MAXIMĂ
NIVEL DE ACCES
UTILIZATOR
UTILIZATOR
UTILIZATOR
15 min
UTILIZATOR
UTILIZATOR
UTILIZATOR
Numai dacă POR = 1
UTILIZATOR
Numai dacă POR = 1
UTILIZATOR
Numai dacă POR = 1
UTILIZATOR
UTILIZATOR
ÎN ATENŢIA INSTALATORULUI
ÎN ATENŢIA INSTALATORULUI
ÎN ATENŢIA INSTALATORULUI
ÎN ATENŢIA INSTALATORULUI
ÎN ATENŢIA INSTALATORULUI
BE16
Numai zona PRINCIPALĂ
ÎN ATENŢIA INSTALATORULUI
ÎN ATENŢIA INSTALATORULUI
6
Numai zone cu ACŢIONARE = BE16
ÎN ATENŢIA INSTALATORULUI
ZONĂ DE AMESTEC
Numai zone cu ACŢIONARE = BE16
TEMP. JOASĂ
ÎN ATENŢIA INSTALATORULUI
SETARE MAX. ÎC
ÎN ATENŢIA INSTALATORULUI
80,5 °C (AT)
ÎN ATENŢIA INSTALATORULUI
45 °C (BT)
ÎN ATENŢIA INSTALATORULUI
SERVICE
99
Numai zone de amestec cu ACŢIONARE=BE16
SERVICE
99
Numai zone de amestec cu ACŢIONARE=BE16
SERVICE
240 sec
Numai zone de amestec cu ACŢIONARE=BE16
SERVICE
240 sec
Numai zone de amestec cu ACŢIONARE=BE16
SERVICE
100 °C
Numai zone BT cu ACŢIONARE =BE16
SERVICE
240 min
Numai zone BT cu ACŢIONARE =BE16
SERVICE
240 min
Numai zone BT cu ACŢIONARE =BE16
SERVICE
240 min
Numai zone BT cu ACŢIONARE =BE16
SERVICE
50 °C
Numai zone cu ACŢIONARE = BE16
SERVICE
20 °C
Numai zone cu ACŢIONARE = BE16
SERVICE
100 °C
Numai zone cu ACŢIONARE = BE16
1
ÎN ATENŢIA INSTALATORULUI
ÎN ATENŢIA INSTALATORULUI
ÎN ATENŢIA INSTALATORULUI
6,0 °C
ÎN ATENŢIA INSTALATORULUI
ÎN ATENŢIA INSTALATORULUI
VALOARE
SETATĂ