4 5 2 Temperatures set by the user

The user can set the hot water delivery temperatures for
both the heating and domestic hot water circuits.
In order to view the set heating temperature value, simply
press either the "+" or "-" button for the heating function one
time only.
The value set by the user, expressed in Celsius, will be
shown on the two-digit right-hand display.
In order to view the set domestic hot water temperature val-
ue, simply press either the "+" or "-" button for the domestic
hot water function one time only.
The value set by the user, expressed in Celsius, will be
shown on the two-digit right-hand display.
70
65
Fig. 39
35
Fig. 40

4 5 3 Monitor function

The two digits on the right-hand side of the display nor-
mally show the current temperature value of the water in
the heating circuit, or else that of the domestic hot water
circuit, if the boiler is currently satisfying a domestic hot wa-
ter request. However, all the temperatures detected by the
board using the "monitor" function can also be displayed.
In order to activate this function, hold down the "SUMMER/
WINTER" button (Fig. 33) until the first digit is displayed as
a flashing "0".
At this point, release the button and press it again immedi-
ately to confirm that you want to access the monitor func-
tion.
At this point, the digit on the left will show the number for
the type of temperature being read, and the two digits on
the right will display the value of the temperature in ques-
tion.
The user can scroll through the various temperatures using
the "+" and "-" buttons for the heating function.
The following table shows the various temperatures that
can be displayed:
Temperature
Delivery temperature
Return temperature
Domestic hot water temper-
ature
Outdoor temperature
Flue gas temperature
Second circuit temperature
(if present)
Fan speed
Ionisation current
The ideal value for the ionisation current is 70-80
(*)
To exit the monitor function, press the "SUMMER/WINTER"
button again.
The appliance automatically exits the function if no button
is pressed for 15 minutes.