- select the type of domestic hot water FLUX SWITCH.
FLOW SWITCH
FLUX SWITCH
FLUX SWITCH
FLOW METER
FLUX METER
FLUX METER
- Once the guided procedure has finished, the REC10 will go to the initial
screen.
Continue with the configuration as follows:
- access the technical parameters as explained in the section "4.1 Access
to the technical parameters" , using the password SERVICE
- select PARAMETERS with the "up" and "down" keys, confirming the
selection
- next change the following parameters:
ENABLE FILLING: set to 1.
Then proceed with the reprogramming of the boiler, carrying out the
operations described in the section "5.2 Programming the boiler" .
5.21 Replacing the REC10 MASTER
b
The system's configuration operations need to be carried out by
professionally qualified personnel of the Technical Assistance Centre.
When replacing the REC10 MASTER, at the subsequent restart it displays
an initial screen with the firmware revision.
Pressing "ok" starts a guided procedure for configuring the system, see
section "5.20 System configuration" . Follow the procedure and carry out the
FROM AKM type of configuration.
MULTI ZONE CONTROLLER
MULTI ZONE CONTROLLER
REC10 V01.26
PRESS ANY KEY TO
PRESS ANY KEY
TO CONTINUE
SELECT THE TYPE
SELECT THE TYPE
OF CONFIGURATION
OF CONFIGURATION
5.22 Replacing the AKM01 board
The configuration operations should be carried out by professionally qualified
personnel of the Technical Assistance Centre. The systems continually
carries out a consistency control between the saved configuration data on
the AKM01 electronic board and those saved in the REC10; therefore, when
replacing the AKM01 electronic board, it can happen that the system detects
an inconsistency between the data saved on the AKM01 and that in the
REC10. In this case, the latter will ask the user which of the two configurations
is to be considered valid; selecting to recuperate the configuration from the
REC10 itself it is possible to avoid reconfiguring the machine:
- select REC10 with the "up" and "down" keys, confirming the selection.
PLANT
PLANT
PLANT
PLANT
PLANT
CONTINUE
FROM AKM
FROM AKM
NEW
NEW
OF CONFIGURATION
CONFIGURATION
5.23 Parameters combustion check
Although the parameters referring to the new combustion control
system ACC (Activate Combustion Control) are preset in the factory, the
simultaneous replacement of both electronics boards (AKM and REC 10
MASTER) could make necessary to re-programming these parameters.
- Access the technical parameters as explained in the section "4.1 Access
to the technical parameters" setting the password SERVICE
- Select COMBUSTION MONITORING with the "up" and "down" keys,
confirming the selection
AIR PURGING CYCLE
EXHAUST PROBE RESET
EXHAUST PROBE RESET
ERROR HISTORY
ALARM HISTORY
COMBUSTION MONITORING
COMBUSTION MONITORING
SERVICE
SERVICE
- Select GAS TYPE
- Set this parameter depending on the type of gas of the boiler. The values
for this parameter are NG = NATURAL GAS - LPG = LPG
COMBUSTION MONITORING
COMBUSTION MONITORING
BOILER TYPE
BOILER TYPE
COMBUSTION OFFSET
COMBUSTION OFFSET
SERVICE
SERVICE
- Select BOILER TYPE
- Set this parameter depending on the type of boiler as shown in the table
BOILER TYPE
BOILER TYPE
SERVICE
SERVICE
EXCLUSIVE 25C
EXCLUSIVE 30C
EXCLUSIVE 35C
SELECT THE
SELECT THE TYPE
TYPE OF
FROM AKM
FROM AKM
REC10
TECHNICAL
TECHNICAL
PARAMETERS
PARAMETERS
VENT CYCLE
GAS TYPE
GAS TYPE
A
B
C
BOILER TYPE
A
B
C
ENGLISH
33