During live transmission of images from analogue cameras, CamDisc HNVR inserts the date and time
l
into the image top right, conforming to ISO 8601. To distinguish different images stored at the same time
from each other, a consecutive image number is displayed after date and time data, separated by a period
or a space.
On principle, always assign a Device name and assign unique Camera names. This facilitates distinction,
l
especially in large projects, not only for live transmission but also for online and offline evaluation. In
addition, you can define camera groups and pool several cameras into logical groups.
Depending on equipment your CamDisc HNVR supports connections to several CamControl LITE
l
stations. Simultaneous support is for up to 6 IP connections, or 5 IP and 1 dial-up connection, or 4 IP and
2 dial-up connections. The number of active CamControl LITE stations connected to the same CamDisc
HNVR at the same time is displayed by the CamControl LITE software below the video window.
Simultaneous connection to several CamControl LITE stations affects CamDisc HNVR performance.
You can enter up to four Telephone numbers / IP addresses that will be processed in the event of an
l
alarm, according to configurable criteria. Field one has top priority. CamDisc HNVR always dials these
numbers consecutively until one of the receivers is contacted. The number of repeats determines the
maximum number of times the list will be processed. In addition, the system can be configured to always
dial all numbers. The same telephone numbers will be used for routine calls and for technical alarms.
Alarm LED will remain active until the telephone number list has been processed according to the set
repeats.
Select option Alarm call in case of defective Hard Disk if you want to send a hard disk error message to a
l
CamControl LITE station. The connection will be established approximately 45 seconds after the error
occurs. If the user confirms the alarm with Report again, another call will be made 6 minutes later. If the
user clicks Do not report again, the transmitter will call to report the hard disk error the next time the error
is detected again with device restart.
Select option Routine call every 24 hours, if you want to report operability of your CamDisc HNVR at
l
regular intervals to a CamControl LITE station. No images will be transmitted during this connection. The
calls will be logged in the logfiles of the transmitter and of the receiver.
CamDisc HNVR checks all connected video signal inputs for video signal failure (faulty camera, faulty
l
video line, low contrast image, e.g. by covered lens). Failure is reported for active cameras if the video
signal has been disturbed for about 10 seconds. The check interval follows the respective recording
interval. In the event of a faulty video signal, recheck takes place after 3 seconds. Recording is resumed
after error elimination. For non recording video cameras failure will be reported after 60 seconds.
Note:
If you require additional features, please refer to the additional configuration options in files
CAMTEL.INI or CAMCTRL.INI. Refer to the respective information in the CamControl LITE or
CamControl PRO software online guides.