Item
Address
Community
MIB
SNMP UPS
Address
User
Remote UPS
Password
4.
Click Add. The UPS device is added to the UPS table.
ReadyDATA OS 1.2
Description
Enter the IP address of the SNMP UPS.
Enter public or private, depending on the manufacturer's requirement or the
UPS's configuration.
From the drop-down list, select the MIB for one of the following
manufacturers:
•
MGE UPS Systems
•
American Power Conversion (APC)
•
SOCOMEC
•
Powerware
•
Eaton Powerware (Monitored)
•
Eaton Powerware (Managed)
•
Raritan
•
BayTech
•
HP/Compac AF401A
•
Cyberpower RMCARD201/RMCARD100/RMCARD202
Enter the IP address of the remote UPS.
For a remote UPS that is attached to a Linux server that is running NUT,
enter the user name to access the remote UPS.
For a remote UPS that is attached to a ReadyNAS, enter monuser. This user
name is required for the ReadyDATA 5200 to access the remote UPS; do not
enter another user name.
For a remote UPS that is attached to a Linux server that is running NUT,
enter the password to access the remote UPS.
For a remote UPS that is attached to a ReadyNAS, enter pass. This
password is required for the ReadyDATA 5200 to access the remote UPS; do
not enter another password.
System Maintenance and Monitoring
155
Need help?
Do you have a question about the ReadyDATA 5200 and is the answer not in the manual?
Questions and answers