6.6 - To enable a booster, when installed
Note For any subsequent filter changes or any operational procedures, please refer to the user guide,
located inside the filter housing access door.
6.7 - Safety sensor calibration (boiling models)
Light intensity varies from site to site, therefore it is recommended that a re-calibration be performed at the
time of the installation.
All direct sunlight must be shaded from the HydroTap
closing any nearby curtains, blinds, etc.
Procedure
Shield the HydroTap
In normal operating mode turn the power off.
Pull both tap levers to the forward position.
Turn the power on.
The safety sensor will calibrate.
Return the levers to the neutral position.
Page 36 of 40
Commissioning
G4 from direct sunlight.
®
802005UK - Residential (Boiling),chilled and sparkling installation instructions - Aug 2015 - v2.01
Press the [MENU] button for main menu.
Press the [Install] button.
Press the [Boost] button.
In the next screen, select [YES] to enable the booster.
Before connecting the power to the booster, water
must be run through for a min. of 30 seconds to purge.
Run the boiling tap for 30 seconds and the allow the
tank to refill.
Dispense boiling water for 30 seconds and check the
booster outlet hose is warm when the boiling water
tank is replenishing.
G4, during the calibration. This can be achieved by
®
Pull both levers
forward
Safety
sensor