Installation instructions Zip HydroTap G4 ® Filtered chilled and sparkling drinking water for residential kitchens. Chilled sparkling model Command-Centre VENTILATION IS ESSENTIAL Affix model number label here 804052UK READ SECTION 2 'VENTILATION' READ BEFORE YOU START 804052UK - Residential chilled and sparkling installation instructions - Sept 2016 - v3.02...
Page 2
The G4 series offers a range of interchangeable taps to suit the customer's needs. Elite HydroTap G4 range ® These standalone taps are directly compatible with the G4 Command-Centre Classic HydroTap G4 range ® Arc / Cube HydroTap G4 range ®...
Section 2 - CO cylinder and regulator 2.1 - 2.4 Connect, secure and test the CO cylinder ............12-13 Step 4 - Install the Command-Centre Section 3 - Command-Centre installation 3.1- Mains water (braided) supply hose ................13 3.2- Chilled and sparkling HydroTap G4 models..............
• Note This product must be fitted to a potable water supply. • Check the appliance rating plate and ensure correct power is available for the appliance. • Check the under counter cupboard floor has sufficient strength to support the Command-Centre when full of water (see page 9 for weights).
G4 Command-Centre is an under counter drinking water appliance with a ® dispensing tap mounted on a sink or worktop, which has been designed for residential applications. The Zip HydroTap G4 Command-Centre utilises a conventional refrigerant compressor to chill the water and uses a ®...
Important safety instructions This manual contains important safety and installation instructions for the Zip HydroTap ® Please read all warnings, installation requirements and installation instructions before installing any Zip HydroTap G4. This system must be installed in accordance with water supply byelaws, ®...
• Do not expose the Zip HydroTap G4 to the elements of nature. ® • Due to the process of continuous improvement, Zip reserves the right to change details mentioned in this manual, without notice. Visit www.zipwater.com/uk to ensure you have the latest copy.
CLAMP AV160/125G4 guide required. (One GPO is for the Zip HydroTap and the other for the Booster heater). NOTE: feed each of the three tubes and NOTE: Check the cable lengths and outlet positions before proceeding. electrical cable evenly in between the legs of...
Technical specifications Chilled and sparkling HydroTap G4 range ® HydroTap ® Chilled, sparkling and filtered. Elite Classic Arc / Cube HydroTap s with mixer taps ® Chilled, sparkling, filtered and mixed hot & cold. Celsius Power Unit Dimensions *Dry weight rating sockets W x D x H (mm)
• Ensure the under counter cupboard floor can support the product weight when full of water (allow an extra 5kg when full). • Sufficient space in the cupboard to install the Command-Centre other components in accordance with these installation instructions. See technical specification, page 9 for dimensions.
• Adequate ventilation must be provided to ensure that the cupboard space temperature does not exceed 1.2 Preferred arrangements 4mm door buffers (at the four corners of each door) supplied with the Command-Centre should be used to provide adequate ventilation in normal usage, see illustration below.
See gas cylinder and MSDS sheet for complete list of warnings. 2.1 Secure the cylinder Secure the gas cylinder supplied to a suitable wall, within 1 metre of the Command-Centre , in an upright position. This is undertaken by screwing the metal bar holding the hook-and-loop strap to a cupboard wall, 200mm above the floor or base of the cupboard.
Test for leaks at these two points Section 3 Command-Centre installation 3.1 Braided hose fitting Install the mains water braided hoses to the Command-Centre before locating in place. 804052UK - Residential chilled and sparkling installation instructions - Sept 2016 - v3.02 Page 13 of 20...
MAINS POWER CHILLED SPARKLING CABLE Note Mains hose length is 750mm Electrical power cable length is 3.0m nom. (Supplied) Position the Command-Centre according to the hose and cable lengths supplied. Clearance envelope 50mm 280mm 50mm External cold isolation valve (not supplied) Note Neither the braided hoses or the tubes supplied with the tap can be lengthened.
POWER OUTLET OUTLET CABLE Note Mains hose length is 750mm. Electrical power cable length is 3.0m nom. Position the Command-Centre according to the hose and cable lengths supplied. Note All plastic pipes Clearance / silicon tubes must be trimmed to size. They...
Settings, of the user manual. Commissioning 4.1 - Select the language Language selection screen Initial commissioning screen Zip BC Sparkling Zip BC Sparkling 4.2 - CO purge • Press the [MENU] button for main menu. • Press the [Install] button.
Commissioning 4.3 - Filter flush Have a bucket or similar container (not supplied) at the ready to hold a quantity of water that will be ejected while the filter flush mode is in operation. Open the filter access door on the front of the HydroTap G4 and ®...
Internal fault Call Zip Service Call an electrician, a plumber, or Zip on 0345 6 005 005 for assistance, service, spare parts or enquiries. End of life disposal The use of this crossed out wheeled bin logo indicates that this product needs to be disposed of separately to any other household waste.
Furthermore this warranty does not displace any statutory warranty, but, to the extent to which Zip is entitled to do so, the liability of Zip under any statutory warranty will be limited at Zip’s option to the replacement of the...
The standard cup referred to in this publication is 167 ml (6 fl oz). The standard glass is 200 ml (7 fl oz). The terms “Zip” and “HydroTap” are registered trade marks of Zip Heaters (Aust) Pty Ltd. Zip products described in this publication are manufactured under one or more of the following patents: AU675601, AU637412, AU635979, GB0422305, GB2065848, US4354049, US5103859, US5099825 and SA2006/08043. Other patents are in force and patent applications are pending.