Zip HydroTap G4 Installation And Operating Instructions Manual

Zip HydroTap G4 Installation And Operating Instructions Manual

Advertisement

Zip HydroTap G4
®
Installation and Operating Instructions
BC Commercial
Affix Model Number Label
Here
801314
801314 v3.05 09.20 HT BC Commercial Instructions
Page 1 of 28

Advertisement

Table of Contents
loading

Summary of Contents for Zip HydroTap G4

  • Page 1: Step

    Zip HydroTap G4 ® Installation and Operating Instructions BC Commercial Affix Model Number Label Here 801314 801314 v3.05 09.20 HT BC Commercial Instructions Page 1 of 28...
  • Page 2: Step

    Tap Options The Zip HydroTap G4 appliance series offers a range of interchangeable taps to suit the customer’s needs Classic Tap These taps are directly compatible with the HydroTap G4 Command Centre. Arc / Cube Tap Elite Tap The Mixer tap range is an additional series of taps that...
  • Page 3: Table Of Contents

    Index HydroTap Specifications Installation Checklist ........................4 General Product Features ......................5 Important Safety Instructions ....................... 6 Warnings and Regulatory Information ..................7 Major Components and Accessories ................... 8 Technical Specification ........................ 9 Before Installation and Site Requirements ................... 10 Installation Instructions STEP 1 - Fit the tap to the benchtop or sink before installing the Command Centre.
  • Page 4: Installation Checklist

    Installation Checklist Before Installation: Read the instructions and check if there is adequate space to mount all of the components. Note: Not all fittings are supplied with the appliance kit. Isolation valves are not supplied. Check the mains water pressure is between 150 - 700kPa and 200 - 700kPa when a booster and /or filter softener is fitted Check the water quality to determine if extra filtration will be required.
  • Page 5: General Product Features

    General Product Features Thank you for purchasing a Zip HydroTap. Please read and follow these instructions carefully to ensure safe and trouble free service. For enquiries and service, please contact your Zip service provider. What is the Zip HydroTap ? The Zip HydroTaps are electronically controlled, filtered, boiling water and chilled water drinking systems for kitchens and tea rooms.
  • Page 6: Important Safety Instructions

    Lifting Take care when lifting the Zip HydroTap Command Centre. Some units may exceed safe lifting limits. If you feel this is beyond your personal capabilities, please seek assistance with the lift. The weights of the units are marked on the packaging.
  • Page 7: Warnings And Regulatory Information

    HydroTap until ready for first use. 10. For water taste and quality reasons, following any non-use period of more than 72 hours, Zip recommends to perform a system flush. Failure to flush the system may affect water quality.
  • Page 8: Major Components And Accessories

    Major Components and Accessories Parts supplied Description Accessories Description 1 x Tap option with hoses HydroTap Booster (Classic tap shown) Water System with connection hoses 1 X HydroTap Command Centre with air and water filters Softener 1 X Mains water and head assembly connection hose 1 x Connector +...
  • Page 9: Technical Specification

    Technical Specifications Commercial Models Cups of Glasses of Boiling Model Chilled Water Boiling and Chilled Water per per Hour BCHA 4 in 1 Hour All in One - Mains All in One - Vented Disabled lever controls (optional accessory) Note Note •...
  • Page 10: Before Installation And Site Requirements

    / or water softener if required. Refer to section 3 & 4, for Installation instructions. • For Zip HydroTap 160/125 &160/175 models, a 220-240V, 10A AC power outlet will be required. For Zip HydroTap 240/175 models, two 220-240V, 10A AC power outlets will be required (one power outlet for the Zip HydroTap and the other for the Booster heater).
  • Page 11: Refer To The Tap Installation Instruction Book 803341

    Section 1 Tap Installation Refer to the Tap installation instruction book 803341. Section 2 Ventilation When installing air flow ducts, the following tools will be required: • Jigsaw and 12mm Drill • Keyhole or Wall Board saw. Recommended Installation showing the correct air flow Note: Note: the hoses the hoses...
  • Page 12 Vent tray, part no. 93540 (optional accessory) Dual exhaust fan kit, part no. 93156 (optional accessory) • Vent Tray Kit Vent Tray HydroTap G4 on Vent Tray Dual Exhaust Fan Kit Page 12 of 28 801314 v3.05 09.20 HT BC Commercial Instructions...
  • Page 13: Product Description

    It is intended to provide pre heating of water before it enters the Zip HydroTap G4 boiling tank. The Booster is supplied as standard equipment with all 240 cup models. However, it may be later installed, as an accessory for the 160 cup models, to increase their delivery to 240 cups.
  • Page 14: Installation Procedure

    Booster Installation Installation Procedure Site requirements • The appliance must only be installed in a frost-free area. Never expose the appliance to frost. • The appliance is designed for wall mounted installation and must to be installed with water connectors facing upwards.
  • Page 15: Braided Hose Connections

    1. The cold water inlet (blue) and hot water outlet (red) are marked on the rating plate. Connect the braided hoses from the ‘Bypass Out’ fitting on the Zip HydroTap, to the water inlet of the booster unit (Marked Blue) and from the outlet of the booster unit (Marked Red) to the ‘Bypass IN’ fitting on the Zip HydroTap Command Centre.
  • Page 16: External Bypass Valve

    Section 4 Filter / Softener Installation An optional, external limescale filter / softener may be fitted to reduce the incidence of scale build up in the hot tank. Mounting the filter head • Choose a suitable location, (cupboard back or side wall) within the reach of the braided hoses.
  • Page 17: Step

    The diverter bypass valve allows the user to choose to have the boiling feed water bypass the internal filter and only be filtered by external filtration. The diverter valve is located at the rear panel of the Zip HydroTap Command Centre on the filter door side. Refer to the image below to determine the correct valve position.
  • Page 18: Model Bc 160/125 And Bc 160/175

    Installation Instructions Models BC 160/125 and BC 160/175 Note: Note: the hoses the hoses need to have a need to have a constant downward constant downward gradient to the Hy- gradient to the Hy- droTap to allow all droTap to allow all water to drain back water to drain back into the tanks.
  • Page 19: Model Bc 240/175

    Installation Instructions Model BC 240/175 Booster Note: the hoses the hoses Note: need to have a need to have a constant downward constant downward gradient to the Hy- gradient to the Hy- droTap to allow all droTap to allow all water to drain back water to drain back into the tanks.
  • Page 20: Model Aio Mains

    Installation Instructions Model All-In-One Mains Pressure Booster Note: the hoses the hoses Note: need to have a need to have a constant downward constant downward gradient to the Hy- gradient to the Hy- droTap to allow all droTap to allow all water to drain back water to drain back into the tanks.
  • Page 21: Model Aio Vented

    Installation Instructions Model All-In-One Vented Options HydroTap AIO Mixer Connections Note: the hoses the hoses Note: need to have a need to have a constant downward constant downward gradient to the Hy- gradient to the Hy- droTap to allow all droTap to allow all water to drain back water to drain back...
  • Page 22: Model 4-In-1 Vented

    Installation Instructions Model 4-In-1 Vented HydroTap Note: the hoses the hoses Note: Mixer need to have a need to have a Connections constant downward constant downward gradient to the Hy- gradient to the Hy- droTap to allow all droTap to allow all water to drain back water to drain back into the tanks.
  • Page 23: Section 6 - Commissioning

    Section 6 Commissioning Do not commission your HydroTap until it is ready to be used! The HydroTap is designed to be installed, commissioned and used within 48 hours. If your HydroTap is left idle before use, a filter change and sanitisation may be required.
  • Page 24: Boiling Calibration

    Commissioning Boiling Calibration Boiling Chilled 10:30 Wed 04,Jul 2018 • Press the calibration button and the system will commence the Boiling calibration procedure. This will take approx 5-6 minutes. Booster • Upon completion, a Booster reminder screen will Boiling Chilled 10:30 Wed 04,Jul 2018 appear and allow you to return home by pressing the [Home] button.
  • Page 25: Safety Sensor Calibration

    Safety Sensor Calibration Sensor Light intensity varies from site to site, therefore it is recommended that a re-calibration be performed at the time of the installation. All direct natural sun light must be shaded from the HydroTap, during the calibration. This can be achieved by closing any nearby curtains, blinds, or by shielding the HydroTap with a dark cloth.
  • Page 26: Troubleshooting Table

    Flow Sensor Fault Internal fault Call Zip Service Call an electrician, a plumber, or Zip free call in Australia on 1800 947 827 for assistance, service, spare parts or enquiries. Page 26 of 28 801314 v3.05 09.20 HT BC Commercial Instructions...
  • Page 27: End Of Life Disposal

    End of Life Disposal In order to help preserve our environment we ask that you dispose of this product correctly. Please contact your local city council for collection centre details. 801314 v3.05 09.20 HT BC Commercial Instructions Page 27 of 28...
  • Page 28: Contact Details

    Zip Water (Aust) Pty Ltd ABN 46 000 578 727 67-77 Allingham St, Condell Park NSW 2200 Postal: Locked Bag 80, Bankstown 1885 Australia zipwater.com | (+612) 9796 3100 | 1800 ZIP TAP (1800 947 827) WMKA00099 AS 3498 The terms “Zip” and “HydroTap” are registered trade marks of Zip Water (Aust) Pty Ltd.

Table of Contents