3. TECHNICAL SPECIFICATIONS

- Power supply:
- Motor output:
- Flashing light/tra c light:
- Accessory output:
-Operating ambient temperature

4. INSTALLATION SAFETY

In order to reach the level of safety required by current regulations, read the following prescriptions carefully.
1) Make all connections in the terminal block after carefully reading the instructions given in this manual and observing the general
rules and technical standards governing electrical systems.
2) Upstream from the installation, t an omnipole miniature circuit breaker with a contact gap of at least 3 mm.
3) If there isn't one already, install a residual current device with a threshold of 30 mA.
4) Check the e ectiveness of the grounding system and connect to it all the parts of the automation tted with a terminal or grounding
cable.
5) Fit at least one external warning device, such as a tra c light or ashing light, along with a warning or danger sign.
6) Fit all the safety devices required by the type of installation, taking into consideration the risks it can cause.
7) Separate the power lines (min. sect. 1.5 mm
5. PRELIMINARY OPERATION
- Before sending a command to the automation, make sure to have selected correctly the type of bollard as follows:
Bollard selection
- Hold down buttons F and + for 5 seconds to select the connected bollard.
- Select the type of bollard using the buttons +/-.
- Press F and + to con rm.
PILLAR B 275/600
PILLAR B 275/800 - XPASS B 275/800C
PILLAR B 275/600.6C SD
PILLAR B 275/800.6C SD - XPASS B 275/800C SD
XPASS B 1200C
STOPPY MBB 219-500.C
STOPPY MBB 219-700.C
- Select network frequency through Ht parameter. (see 3rd level programming).
- (Hydraulic bollards only) Select the pressure switch type with the parameter
- Check the connection method for simultaneous operation, if controlling multiple deterrent devices simultaneously (see paragraph 10).

6. INPUT AND OUTPUT FUNCTIONALITY AND CONNECTIONS

L N E
230Vac +-10%, 50/60Hz
230Vac; 13A max
230Vac; 40W max
24Vac; 1A max
-25° +60° C

3.1 CONTROL PANEL DIMENSIONS

2
) from the low-voltage signal lines (min. sect. 0.5 mm
J2
6.1
LINE
230V
230V 50/60Hz power supply with varistor internal protection and 5A T (5x20) plus 16A T (6.3x32) fuses.
Connect the phase and neutral as shown on the screen printing. Use a cable type H07RN-F 2x1.5+E min.
Connect the yellow/green wire of the power supply mains to the earth terminal of the appliance.
Control unit
-Operating ambient humidity
-Protection degree
-Storage ambient temperature
BOLLARD TABLE
EASY Ø115-500 - STOPPY B 115/500
EASY Ø200-700 - STOPPY B 200/700
NOT AVAILABLE
NOT AVAILABLE
NOT AVAILABLE
NOT AVAILABLE
(see 3rd level programming).
POWER TERMINAL BLOCK
- 25 -
up to 95%
non condensing
IP55
-25° +60° C
2
) in the ducts.
STOPPY Ø210-500
STOPPY Ø210-700
NOT AVAILABLE
NOT AVAILABLE
NOT AVAILABLE