Contact Closure - Future Automation CHS Series Installation Instructions Manual

Ceiling hinge & swivel/ceiling hinge & swivel with telescope
Table of Contents

Advertisement

CHS - Ceiling Hinge & Swivel

Contact Closure

- Use an RJ45 connector in the CCI
socket on the control box to operate
via contact closure
PIN
DESCRIPTION
1
12V SUPPLY
2
3
GROUND
4
5
DEVICE LEFT
6
DEVICE RIGHT
7
DEVICE HOME
8
DEVICE IN
Any contact closure input
whilst the mechanism is in
motion will stop the movement
and all other contact closure
commands will be disabled for
1 second.
NOTE:
Earlier versions of the control board
may not have these contact closure
LED indicators.
Page 14 of 18 // email info@futureautomation.co.uk tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
ACTION
12V SUPPLY - CURRENT LIMITED
PIN 2 NOT USED
GROUND
PIN 4 NOT USED
Momentary short to GROUND (pin 3), will
make device go OUT LEFT limit.
Momentary short to GROUND (pin 3), will
make device go OUT RIGHT limit.
Momentary short to GROUND (pin 3),
makes device go OUT CENTERED.
Momentary short to GROUND (pin 3),
makes device go IN.
LED 1
LED 2
LED 3
LED 4
LED 5
WIRE / CABLE
CONTACT CLOSURE
568A
568B
LED INDICATOR
W/G
W/O
G
O
W/O
W/G
BL
BL
W/BL
W/BL
LED 4
O
G
LED 3
W/BR
W/BR
LED 2
BR
BR
LED 1
CONTACT CLOSURE INPUT

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CHS Series and is the answer not in the manual?

This manual is also suitable for:

Chs 3Chs 4Chs 5Chst 3Chst 4Chst 5 ... Show all