CHS - Ceiling Hinge & Swivel
Contact Closure
- Use an RJ45 connector in the CCI
socket on the control box to operate
via contact closure
PIN
DESCRIPTION
1
12V SUPPLY
2
3
GROUND
4
5
DEVICE LEFT
6
DEVICE RIGHT
7
DEVICE HOME
8
DEVICE IN
Any contact closure input
whilst the mechanism is in
motion will stop the movement
and all other contact closure
commands will be disabled for
1 second.
NOTE:
Earlier versions of the control board
may not have these contact closure
LED indicators.
Page 14 of 18 // email info@futureautomation.co.uk tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
ACTION
12V SUPPLY - CURRENT LIMITED
PIN 2 NOT USED
GROUND
PIN 4 NOT USED
Momentary short to GROUND (pin 3), will
make device go OUT LEFT limit.
Momentary short to GROUND (pin 3), will
make device go OUT RIGHT limit.
Momentary short to GROUND (pin 3),
makes device go OUT CENTERED.
Momentary short to GROUND (pin 3),
makes device go IN.
LED 1
LED 2
LED 3
LED 4
LED 5
WIRE / CABLE
CONTACT CLOSURE
568A
568B
LED INDICATOR
W/G
W/O
G
O
W/O
W/G
BL
BL
W/BL
W/BL
LED 4
O
G
LED 3
W/BR
W/BR
LED 2
BR
BR
LED 1
CONTACT CLOSURE INPUT
Need help?