Guidelines and MANUFACTURER Declaration – electromagnetic IMMUNITY
CLINIPORATOR can be used in the electromagnetic environment specified below. The client or user of
CLINIPORATOR should ensure that it is used in such environment.
Immunity test
RF conducted
IEC 61000-4-6
RF emitted
IEC 61000-4-3
NOTE 1: At 80 MHz and 800 MHz, the separation distance for higher frequency interval applies.
NOTE 2: These guidelines might not apply in all situations. Electromagnetic propagation is influenced by absorption
and reflection of structures, objects and people.
a
The field intensities for fixed transmitters, such as radio telephones (mobile/cordless) and land mobiles base
stations, amateur radio operator equipment, radio transmitter in AM and FM and TV transmitters cannot be
foreseen theoretically with accuracy. To evaluate an electromagnetic environment caused by fixed RF
transmitters, an electromagnetic analysis on site should be performed. If the field intensity measured in the
location - where the [EM DEVICE or the EM SYSTEM] is used - exceeds the above indicated applicable
compliance level, the operation of the [EM DEVICE or the EM SYSTEM] should be put on watch. If abnormal
performances are registered, additional measures might be necessary, such as a different orientation or position
of the [EM DEVICE or the EM SYSTEM].
b
The field intensity in the frequency interval from 150 kHz to 80 MHz should be less than [V1] V/m.
62
Test level of IEC 60601
3 V eff
from 150 kHz to 80 MHz
3 V/m
from 80 MHz to 2.5 GHz
Cliniporator model EPS02 – User manual
Compliance level
Portable
communication devices should not
be
CLINIPORATOR - including cables -
than the recommended separation
distance calculated by the equation
applicable
frequency.
Recommended
distance.
3 V
d = 1,2 x √P
d = 1,2 x √P from 80 MHz to 800
MHz
3 V/m
d = 2,3 x √P from 800 MHz to 2.5
GHz
where P is the maximum output
transmitter
according
manufacturer and d is the suggested
separation distance in metres (m).
The fixed transmitters field intensities,
determined by an electromagnetic
analysis in loco
the compliance level
for each frequency
Interference can occur near devices
marked with the following symbol:
Guidelines – electromagnetic
environment
and
mobile
used
nearer
any
part
to
the
transmitter
separation
value
in
watts
to
the
transmitter
a
should be lower than
b
level.
RF
of
(W)

Advertisement