Connecting the valve terminal/valve sensor terminal
4-34
4. Installation
CAUTION
The position of the pins is different depending
on whether they are in the form of plugs or
sockets.
•
The connections of the input and output
modules are in the form of sockets.
•
The connections of the field bus interface
and those of the operating voltage
connections are in the form of plugs.
The pin assignment can be found in the
chapters which follow.
When you have selected suitable cables,
connect them according to steps 1 ... 7.
1. Open the plugs/sockets as follows
(see diagram):
•
Power supply socket
Insert the power supply socket into
the operating voltage connection on the
valve terminal. Unscrew the housing of the
socket and remove it. The socket remains
inserted in the operating voltage connection.
•
Sensor plug and field bus socket
Unscrew the centre knurled nut.
0503f