Festo VIFB11-02 Series Manual page 106

Valve terminal/valve sensor terminal with field bus connection
Table of Contents

Advertisement

VIFB11 - 02
0.00
No.
0
0.03
0.01
Fig. 5/3: Outputs of the valve locations
Valve
Valve type
location no.
2
unilaterally
operated
9
bilaterally
operated
Fig. 5/4: Example - Addressing and activating valves
5-10
5. Commissioning
The assignment of the outputs to the relevant
valve locations is shown in the diagram below.
Outputs of the
valve locations
0.02
0.04
0.06
0.08
0.10
Valve locations
No.
No.
No.
No.
No.
1
2
3
4
5
0.05
0.07
0.09
0.11
Outputs of the
valve locations
Example:
Addressing and activating valves
Output
Bit
Remarks
contents
O0.04
1
Valve solenoid coil active
O0.05
X
Output not evaluated,
Bit contents without meaning
O1.02
0
Upper valve solenoid coil not
active
O1.03
1
Lower valve solenoid coil active
0.14
1.02
0.12
1.00
No.
No.
No.
No.
6
7
8
9
0.13
0.15
1.01
1.03
9902d