3. Installation
3.3

Connecting the valve terminal

Festo P.BE-MIDI/MAXI-03-EN en 0209f
Please note
Some connections are covered with adhesive foil to pre-
vent dirt from entering. Remove all adhesive foil from
the connections.
If not used, seal:
– valve locations with cover plates.
– work connections (2, 4) with blanking plugs.
Observe the following sequence when connecting the
work air, depending on the tool you are using.
– Any sequence is possible in the case of screw
connectors with socket head screw.
– In the case of screw connectors with external
hexagon connection must be made from left to right
(space for the wrench).
3-9